Skip to main content
CityRuleLookup

Titusville, FL Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Down-lit fixture rule
Required for all fixtures, Sec. 30-192(a)
Freestanding fixture height
40 ft citywide; 25 ft in PID
Timer/cutoff requirement
Required on non-security lighting
Bollard exemption
Low-voltage walkway lighting exempt from down-lit rule
LED incentive
Permit fees waived for low-power fixtures

Summary

Titusville's Land Development Regulations require all freestanding and building-mounted light fixtures to be down-lit and cap freestanding fixtures at forty feet, while Sec. 30-193 mandates timers or cutoff switches on outdoor non-security lighting and lets low-voltage bollard lighting skip the down-lit rule. The City waives lighting permit fees for low-power LED designs.

All freestanding and building mounted light fixtures shall be down-lit. ... Sec. ... 30-193. - Other site lighting standards. (a)Light timers/cutoff switches are required for all outdoor non-security lighting fixtures.(b)Low voltage, low intensity walkway light (i.e. bollard lighting) are permissible and are not required to be down-lit.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 54 Update 1 | Land Development Regulations: Supplement 19 Update 1 | Technical Manuals: Supplement 10 Update 1).

Full Breakdown

Titusville, Florida (Brevard County) sets site lighting standards in Land Development Regulations Division 5, Chapter 30, intended to allow lighting for parking lots, secured areas, walkways and site features while protecting neighboring properties from intrusive light. Sec. 30-192(a) requires that all freestanding and building-mounted light fixtures be down-lit, and Sec. 30-192(c) caps any freestanding light fixture at forty feet in height. Sec. 30-193(a) adds a shielding-adjacent requirement: light timers or cutoff switches are required for all outdoor non-security lighting fixtures, so decorative and site lighting cannot burn all night without a control.

Low-voltage, low-intensity walkway lighting such as bollard fixtures is exempt from the down-lit requirement under Sec. 30-193(b). The City encourages low power consumption fixtures such as LED and waives site lighting permit fees as an incentive for developments that use them, per Sec. 30-193(c), though other site and building fees still apply. Upward-directed lighting is allowed only when aimed at flag poles, fountains, building facades or landscaping, and only when directed away from adjacent properties and rights-of-way, subject to Administrator approval under Sec. 30-193(d). A stricter regime applies within Planned Industrial Development (PID) sites: Sec.

30-194 requires artificial lighting to be directed away from adjacent properties and streets and caps free-standing PID fixtures at twenty-five feet, lower than the citywide forty-foot cap. Off-street parking areas must be illuminated to a minimum of one footcandle at eye level across the parking surface during operating hours under Sec. 30-192(d). These are development-review standards enforced at site plan and permit review, so noncompliant lighting is generally corrected through the permitting process rather than after-the-fact citations for existing single-family homes.

Violations & Fines

Lighting installed without required shielding, timers or cutoff switches, or a freestanding fixture exceeding the forty-foot height cap (twenty-five feet in Planned Industrial Development), is a Land Development Regulations violation caught at site plan review or building permit inspection; a certificate of occupancy can be withheld until fixtures are corrected, and existing noncompliant lighting can be referred to the Municipal Code Enforcement Board for a compliance order.

Frequently Asked Questions

Does Titusville require outdoor lights to be shielded or down-lit?
Yes. Sec. 30-192(a) of the Land Development Regulations requires that all freestanding and building-mounted light fixtures be down-lit, meaning the light source is directed downward, with narrow exceptions for low-voltage bollard walkway lighting and approved accent lighting on flagpoles, fountains or building facades.
Is there a height limit on outdoor light poles?
Freestanding light fixtures citywide are capped at forty feet under Sec. 30-192(c). Inside a Planned Industrial Development, the limit drops to twenty-five feet under Sec. 30-194(b), and PID fixtures must also be approved by the Administrator for design compatibility with the business park.
Do outdoor lights need timers in Titusville?
Yes. Sec. 30-193(a) requires light timers or cutoff switches for all outdoor non-security lighting fixtures. The City also waives site lighting permit fees for developments using low power consumption fixtures such as LED, though other applicable site and building permit fees still apply under Sec. 30-193(c).

Sources & Official References

Other rules in Titusville

All Titusville rules

Florida rules heatmap·Compare Titusville to another location·View the Florida outdoor lighting overview

Get notified when Dark Sky Rules in Titusville, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Dark Sky Rules in Nearby Cities

How other cities in Brevard County handle dark sky rules.

Palm Bay, FL
Some Restrictions