Lawton, OK Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing section
Lawton City Code § 6-1-5-187(A)(3)(b)
Light trespass cap
0.1 foot-candles at property line
Parking-lot illumination range
0.2 to 4.0 foot-candles average
Uniformity ratio limit
4:1 average to minimum
Full cutoff trigger
Fixtures over 2,000 initial lumens
Adopted
Ord. No. 11-53, § 2 (11-29-2011)

Summary

Lawton City Code Section 6-1-5-187 limits how much light a development's site lighting can throw onto a neighboring residential lot: no more than 0.1 foot-candles measured beyond the property line. The same section caps overall parking-lot illumination and requires full cutoff fixtures for brighter lights.

3.The installed fixture height, spacing, mounting location, illumination levels, as well as the number and type of fixtures shall be reviewed as part of the site plan. The lighting design must meet the following criteria:a.Illumination level: The average maintained illumination level shall be not more than 4.0 foot-candles or less than 0.2 foot-candles, with a maximum uniformity ratio (average to minimum) of 4:1 over the entire parking area.b.Light trespass onto to adjacent residential properties: The illumination level beyond the property line shall not be greater than 0.1 foot-candles.c.Glare control: Full cut-off fixtures (ninety (90) degrees from vertical) shall be required for all light sources greater than two thousand (2,000) initial lumens (approximately the equivalent of a one hundred fifty (150) watt incandescent bulb).

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 2 Update 1).

Full Breakdown

Section 6-1-5-187(A)(3) sets three numeric benchmarks the city reviews as part of a project's site plan. 0 foot-candles, with a maximum uniformity ratio of 4:1 between the average and the minimum reading, so a lot cannot be lit unevenly with dark pockets and glaring hot spots. 1 foot-candles, a low threshold meant to keep a commercial or multi-family lighting plan from washing out a neighboring yard at night. Third, glare control requires full cutoff fixtures, meaning no light escapes above ninety degrees from vertical, for any light source rated above 2,000 initial lumens, about the output of a 150-watt incandescent bulb.

All three figures are reviewed together at the site-plan stage alongside fixture height, spacing, and mounting location, and the section frames the whole standard around one stated purpose: providing adequate parking-lot security lighting while protecting adjacent residential properties from that same lighting. 1 foot-candles crossing into a neighboring residential lot does not meet the section as written, regardless of how the interior parking area is lit.

Violations & Fines

A site-lighting plan that fails the 0.1 foot-candle light-trespass cap can be rejected or conditioned at site-plan review before a certificate of occupancy issues. If lighting is installed differently than approved and later measured over 0.1 foot-candles at a residential property line, the project is out of compliance with Section 6-1-5-187. The section sets no separate fine, so enforcement of an as-built violation falls to Section 1-1-119's general penalty: up to a $750 fine, up to sixty days in jail, or both.

Frequently Asked Questions

How much light can spill onto my yard from a neighboring Lawton development?
No more than 0.1 foot-candles measured at the property line, under Section 6-1-5-187(A)(3)(b). That cap applies specifically to light trespass onto adjacent residential properties from a reviewed site-lighting plan, separate from the 0.2 to 4.0 foot-candle range allowed within the lit parking area itself.
What is a foot-candle and why does Lawton's code use it?
A foot-candle measures how much light actually lands on a surface. Section 6-1-5-187 uses it to set three numbers at once: overall parking-lot brightness, evenness across the lot, and the light-trespass ceiling of 0.1 foot-candles at a residential property line.
Does Lawton require a light-trespass study before approving a project?
The illumination levels, including the 0.1 foot-candle residential cap, are reviewed as part of the site plan under Section 6-1-5-187. Developers submit photometric fixture data covering height, spacing, and mounting location so the city can confirm the plan meets that cap before approval.

Sources & Official References

Other rules in Lawton

All Lawton rules

Compare Lawton to another location·View the Oklahoma outdoor lighting overview

Get notified when Light Trespass & Shielding in Lawton, OK changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.