Skip to main content
CityRuleLookup

Wausau, WI Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Fixture visibility
Not visible from residential lot
Property-line cap
0.50 foot-candles above ambient
Residential lumens/acre
10,000 max
Nonresidential lumens/acre
50,000 max
On-site average, residential
1.0 foot-candle max
On-site average, nonresidential
3.0 foot-candles max

Summary

Wausau bars outdoor light fixtures from being aimed so the light element is visible from any residential property, and caps illumination at the property line to 0.50 foot-candles above ambient conditions. On-site averages are limited to 1.0 foot-candle in residential districts and 3.0 in nonresidential districts under Wausau Municipal Code § 23.06.20(5).

(a)In no instance shall an exterior lighting fixture be oriented so that the lighting element (or a clear shield) is visible from a property located within a residential zoning district. The use of shielded luminaries and careful fixture placement is encouraged so as to facilitate compliance with this requirement. ... (c)Intensity of illumination.1.In no instance shall the amount of illumination attributable to exterior lighting, as measured at the property line, exceed 0.50 foot-candles above ambient lighting conditions on a cloudless night; and shall not exceed a total of 10,000 lumens per acre for residential land uses and 50,000 lumens per acre for all other land uses.2.The maximum average on-site lighting in nonresidential zoning districts shall be 3.0 foot-candles.3.The maximum average on-site lighting in residential zoning districts shall be 1.0 foot-candles. ... 5.Reflected glare onto nearby buildings, streets, or pedestrian areas is prohibited.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 12 Update 2).

Full Breakdown

20(5)(a): no exterior lighting fixture may be oriented so that the lighting element, or even a clear shield around it, is visible from a property inside a residential zoning district, and the code encourages shielded luminaries and careful fixture placement to meet that standard. Subsection (c) backs that placement rule with hard numbers. 50 foot-candles above ambient nighttime conditions, and total output is capped at 10,000 lumens per acre for residential land uses and 50,000 lumens per acre for every other land use. 0 foot-candles once the business closes and use fully recessed under-canopy fixtures.

The same subsection bans reflected glare onto nearby buildings, streets, or pedestrian areas outright. Because these are numeric, measurable standards rather than a design preference, the Zoning Administrator can verify a complaint with a foot-candle meter at the shared property line rather than relying on a visual judgment call.

Violations & Fines

A fixture aimed so its light element is visible from a residential property, or exterior lighting that exceeds 0.50 foot-candles above ambient conditions at the property line, violates section 23.06.20(5). It is enforced through the general Title 23 penalty in section 1.01.110, a forfeiture of not less than $10.00 nor more than $200.00 per offense, with each day of a continuing violation a separate offense.

Frequently Asked Questions

How bright can my neighbor's outdoor lighting be at my property line?
Section 23.06.20(5)(c) caps it at 0.50 foot-candles above ambient nighttime conditions, measured at the property line, with a further ceiling of 10,000 lumens per acre for residential uses and 50,000 lumens per acre for other land uses.
Can I be cited if I can see the bulb of my neighbor's light from my yard?
Potentially, yes. Section 23.06.20(5)(a) bars orienting a fixture so the lighting element or its clear shield is visible from a residential property, so a light aimed toward, rather than shielded away from, an adjoining home does not meet the standard.
Are gas station and car lot lights held to the same limit?
No, they get a higher allowance. Section 23.06.20(5)(c)(4)(b) permits auto display lots and gas station pump islands to average up to 25.0 foot-candles while open, as long as the lighting dims to 3.0 foot-candles after closing and canopy fixtures are fully recessed.

Sources & Official References

Other rules in Wausau

All Wausau rules

Compare Wausau to another location·View the Wisconsin outdoor lighting overview

Get notified when Light Trespass & Shielding in Wausau, WI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Light Trespass & Shielding in Nearby Cities

How other cities in Marathon County handle light trespass & shielding.

Rothschild, WI