Glynn County, GA Parking Rules: Loading Zones (2026)
Key Facts
- Minimum space size
- 10 ft wide, 50 ft long, 14 ft high
- Small retail exemption
- None required under 2,000 sq ft
- Location rule
- Must be on same lot as building
- Street rule
- Vehicles may not block public street/alley
- Governing section
- Zoning Ordinance § 612
Summary
In unincorporated Glynn County, any new commercial, industrial, government or multi-family building must provide off-street loading space sized at least ten feet wide, 50 feet long and 14 feet high under the zoning ordinance. The number of required spaces scales with floor area, and loaded vehicles can never stand in or block a public street, walk or alley.
Areas suitable for loading and unloading motor vehicles in off-street locations shall hereafter be required at the time of the initial construction of any building or structure used or arranged to be used for commercial, industrial, government, or multi-family residential purposes. ... 612.2Amount of Area Required for Each Loading Space. Each off-street loading and unloading space required by the provisions of this ordinance shall be at least ten feet in width, 50 feet long and 14 feet high. Such space shall be clear and free of obstructions at all times. ... 612.4Adequacy of Loading Area. All uses, whether specified in this ordinance or not, shall provide off-street loading areas sufficient for their requirements. Such space shall be adequate so that no vehicle being loaded or unloaded in connection with normal operations shall stand in or project into a public street, walk, alley, or way.
Full Breakdown
Section 612 of the Glynn County Zoning Ordinance, Off-Street Loading and Unloading Area Requirements, applies at the time of initial construction of any building used for commercial, industrial, government or multi-family residential purposes. 1 sets a sliding scale: a retail use under 2,000 square feet needs no dedicated loading space, a retail use between 2,000 and 25,000 square feet needs one space, and wholesale, industrial, governmental and institutional uses, including public-assembly places, hospitals and schools, need one space for the first 25,000 square feet of floor area and then step up according to a published table, for example two spaces from 25,000 to 99,999 square feet and three spaces from 100,000 to 159,999 square feet, plus one additional space per 100,000 square feet beyond that.
Multi-family buildings follow their own scale: none under ten units, two parking spaces in lieu of a loading space for ten to 30 units, and two spaces for the first 30 units plus one more per additional 30 units above that. 2 fixes the minimum size of each required space at ten feet wide, 50 feet long and 14 feet high, kept clear of obstructions at all times. 4 makes clear that loading and unloading, however it is handled, can never let a vehicle stand or project into a public street, walk, alley or way.
Violations & Fines
A commercial, industrial or multi-family project built without the loading spaces Section 612.1 requires, or with spaces smaller than the ten-by-50-by-14-foot minimum in Section 612.2, is out of compliance with the zoning ordinance, and Community Development can withhold a Certificate of Occupancy until it is corrected. A delivery vehicle that stands or projects into a public street, sidewalk or alley while loading violates Section 612.4 regardless of how much loading space the site otherwise provides.
Frequently Asked Questions
Does every commercial building in unincorporated Glynn County need a loading dock?
How big does a required loading space have to be?
Can a business count its loading space as part of required parking?
Sources & Official References
Other rules in Glynn County
Compare Glynn County to another location·View the Georgia parking rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.