Skip to main content
CityRuleLookup

New Berlin, WI Parking Rules: Loading Zones (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Trigger size
1 space per 5,000-24,999 sq ft of building
Largest standard tier
5 spaces at 175,000-249,999 sq ft
Minimum space size
10 ft wide, 79 ft long, 14 ft clearance
Surface
Asphalt or concrete paving required
Exempt district
City Center District

Summary

New Berlin requires business and industrial lots, other than in the City Center District, to provide off-street loading space under Section 275-57 C. The number of spaces scales with building size, from one space for a 5,000-to-24,999-square-foot building up to five spaces near 250,000 square feet, with each space at least ten feet wide and 79 feet long.

C.Off-street loading requirements.(1)Applicability. On every lot on which a business or industrial use, with the exception of the City Center District, is hereafter established, space with access to a public street or alley shall be provided as indicated below for the loading and unloading of vehicles off the public right-of-way.(2)Minimum number of required spaces. The number of loading spaces required is as follows: ... Gross Floor Area of Building (square feet) Required Loading Spaces 5,000—24,999 1 25,000—49,999 2 50,000—99,999 3 100,000—174,999 4 175,000—249,999 5 ... (4)Minimum area. The minimum area for each loading space, excluding the area needed to maneuver, shall be ten feet wide and 79 feet long with a height clearance of 14 feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Municipal Code: Supplement 3 Update 1).

Full Breakdown

Section 275-57 C of the Code of Ordinances requires every lot with a business or industrial use, except in the City Center District, to provide loading space with access to a public street or alley for loading and unloading vehicles off the public right-of-way. Table 275-57-4 sets the minimum count by gross floor area: one loading space for 5,000 to 24,999 square feet, two for 25,000 to 49,999, three for 50,000 to 99,999, four for 100,000 to 174,999, and five for 175,000 to 249,999 square feet, with one additional space for every additional 74,000 square feet, or fraction of it, above 250,000 square feet.

Each loading space has to measure at least ten feet wide and 79 feet long, excluding maneuvering area, with a 14-foot height clearance, and the surface has to be asphalt or concrete. No part of a truck or van being loaded or unloaded can extend into a public right-of-way, and single-bay docks need enough apron area for the largest vehicle using the facility to maneuver without backing into the street. Table 275-57-5 sets minimum truck apron length and dock approach distances by truck length and berth width; for example a 40-foot truck needs a 46-foot apron and an 86-foot dock approach at a ten-foot berth, tightening to a 39-foot apron and 79-foot approach at a 14-foot berth. Loading, trash and utility areas also have to be screened from street and side-path views under Section 275-56 G(2) and Section 275-59 D(5).

Violations & Fines

Failing to provide the required loading spaces, or letting a truck being loaded block the public right-of-way, is a Chapter 275 violation enforced under Sections 275-67 through 275-69. The Director gives written notice with 30 days to correct a nonemergency violation, and continued noncompliance is referred for prosecution under the general penalty in Section 1-18: $5 to $1,000 forfeiture plus costs for a first offense, $10 to $1,000 for a repeat offense within a year.

Frequently Asked Questions

Does a small retail building in New Berlin need a loading dock?
Once gross floor area reaches 5,000 square feet, Table 275-57-4 requires at least one off-street loading space, ten feet wide and 79 feet long with 14 feet of clearance, unless the building sits in the City Center District, which is exempt from Section 275-57 C.
Can a delivery truck load from the street in New Berlin?
No part of a truck or van being loaded or unloaded may extend into the right-of-way of a public street under Section 275-57 C(5)(b), so the loading space and apron have to be large enough to keep the whole vehicle off the pavement.
How many loading spaces does a 100,000-square-foot warehouse need?
Four. Table 275-57-4 sets four required loading spaces for buildings between 100,000 and 174,999 square feet of gross floor area, rising to five spaces once the building reaches 175,000 square feet.

Sources & Official References

Other rules in New Berlin

All New Berlin rules

Compare New Berlin to another location·View the Wisconsin parking rules overview

Get notified when Loading Zones in New Berlin, WI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Loading Zones in Nearby Cities

How other cities in Waukesha County handle loading zones.

Waukesha, WI
Some Restrictions