San Angelo, TX Building Safety: Carbon Monoxide Detectors (2026)
Key Facts
- Adopted code
- 2021 IRC, Sec. R315.3 amended
- Standard placement
- Within 12 ft of bedroom door
- Fuel-appliance rule
- Alarm goes inside that bedroom
- Enforcement
- Inspections and permits department
- Violation class
- Class C misdemeanor
Summary
San Angelo's amended Residential Code requires a carbon monoxide alarm outside each sleeping area, and inside the bedroom itself if a fuel-burning appliance sits in that bedroom or its bathroom. The rule rides on the same 2021 IRC adoption as the smoke alarm standard.
Section R315.3 Carbon monoxide alarms - Location. Carbon monoxide alarms in dwelling units shall be installed outside of each separate sleeping are within 12 feet of the outside edge of the bedroom door. Where a fuel burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 10).
Full Breakdown
Sec. 3, Location, for carbon monoxide alarms: they must be installed outside of each separate sleeping area within 12 feet of the outside edge of the bedroom door, mirroring the smoke alarm placement rule in the same amendment section. Where a fuel-burning appliance, such as a gas furnace, water heater or space heater, is located within a bedroom or its attached bathroom, the alarm must instead be installed inside that bedroom, putting the detector closer to the combustion source rather than in the hallway. This sits in the same Division 3 residential code adoption that also governs foundation anchorage, wind and snow design loads, and frost line depth for the city, all amended into the base 2021 IRC that sec.
092 adopts for one- and two-family dwellings. The inspections and permits department administrator, as building official, verifies alarm placement as part of required residential inspections before a certificate of occupancy issues. Because the amendment is embedded in the adopted residential code rather than a standalone ordinance, it applies citywide to new construction and to alterations that trigger a residential building permit under the same chapter.
Violations & Fines
Failing to install a carbon monoxide alarm in the location required by amended Section R315.3 is a violation of the adopted Residential Code and a Class C misdemeanor under sec. 4.04.003, fined under the general penalty in sec. 1.01.009: up to $500 per violation, with each day of continued noncompliance a separate offense.
Frequently Asked Questions
Where must carbon monoxide alarms go in a San Angelo home?
What if my gas water heater is inside a bedroom or its bathroom?
Is a CO alarm required in every San Angelo home?
Sources & Official References
Other rules in San Angelo
Texas rules heatmap·Compare San Angelo to another location·View the Texas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.