Tamarac, FL Building Safety: Carbon Monoxide Detectors (2026)
Key Facts
- Governing section
- Tamarac Code Sec. 12-234(1)c
- Standard referenced
- FBC-Residential Section R315
- Applies to
- Permitted vacation rentals
- Compliance check
- Inspection before permit, annual after
- Enforcement
- Special magistrate, progressive fines
Summary
In the City of Tamarac, every vacation rental must have a working carbon monoxide alarm system, not just a general house rule. City Code Sec. 12-234(1)c ties the mandate to the CO-alarm section of the Florida Building Code-Residential and makes it a condition of holding a vacation rental permit.
c.Smoke and carbon monoxide (CO) detection and notification system. A smoke alarm and carbon monoxide (CO) alarm system shall be required to be installed and maintained on a continuing basis consistent with the requirements of ... Section R315, Carbon Monoxide Alarms, of the Florida Building Code—Residential.
Full Breakdown
The City of Tamarac's vacation rental article sets minimum life/safety requirements before the Community Development Department will issue or renew a vacation rental permit. Under Sec. 12-234(1)c, a carbon monoxide (CO) alarm system must be installed and maintained on a continuing basis, and the standard the city references is Section R315, Carbon Monoxide Alarms, of the Florida Building Code-Residential. The same subsection requires a smoke alarm system and a portable 2A:10B:C dry chemical fire extinguisher on every floor, inspected under NFPA 10. Compliance is checked, not just declared: Sec.
12-235 requires an initial inspection before the city issues the vacation rental certificate of compliance, and annual re-inspections after that, with any deficiency needing correction and re-inspection within thirty calendar days or the certificate is suspended. A responsible party named on the permit must keep the CO alarm and the rest of the life/safety package functional, since Sec. 12-231 makes upkeep of the unit an affirmative duty of that person. Failure to maintain a required CO alarm is a violation of Article XIII, enforceable under Sec.
12-238 through the city's progressive enforcement program: warnings for a first-time violation, then citations, with fines set by city commission resolution for repeat violations, and possible suspension or revocation of the vacation rental permit by the city's special magistrate.
Violations & Fines
Missing or non-functioning CO alarms found during a Sec. 12-235 inspection block issuance or renewal of the vacation rental certificate of compliance. A confirmed violation triggers the Sec. 12-238 progressive enforcement track: a warning with a correction period for a first offense, then a citation and fines set by city commission resolution, with the special magistrate authorized to suspend or revoke the vacation rental permit for repeat or unaddressed violations.
Frequently Asked Questions
Does Tamarac require CO alarms in every vacation rental?
Who checks that the CO alarm is actually working?
What happens if a vacation rental is missing a CO alarm?
Sources & Official References
Other rules in Tamarac
Florida rules heatmap·Compare Tamarac to another location·View the Florida building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Carbon Monoxide Detectors in Nearby Cities
How other cities in Broward County handle carbon monoxide detectors.