Yonkers, NY Building Safety: Carbon Monoxide Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Detector placement
within 10 ft of sleeping rooms
Hotels/motels
1 detector per 10,000 sq ft/floor
Standard
UL 2034-96 Second Edition
Enforcing agency
Building Commissioner
Penalty
$200-$1,000 fine, up to 15 days jail
Battery replacement
owner replaces at tenant turnover

Summary

Yonkers City Code § 56-170 requires every residential or mixed-occupancy building with one or more residential units to install approved carbon monoxide detectors, with at least one placed within 10 feet of every sleeping room. Units next to an attached garage need a dedicated detector, and hotels get one per 10,000 square feet of floor area.

Except as hereinafter provided, every building of residential or mixed occupancy and having one or more residential units shall be equipped with approved carbon monoxide detectors in accordance with this article. For purposes of this article "residential unit" includes multiple-family dwelling as defined in § 43-8 of the Zoning Code of the City of Yonkers. ... Not less than one approved carbon monoxide detector shall be installed in a residential unit. The detector shall be installed within 10 feet of all rooms used for sleeping purposes.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4745274; v31 updated 2025-10-28; through 10-28-2025).

Full Breakdown

L. No. 4-2001, covers virtually every occupied unit in the city. Section 56-170A applies to any building of residential or mixed occupancy with one or more residential units, defining "residential unit" to include multiple-family dwellings under § 43-8 of the Zoning Code. Only two narrow exceptions exist: a unit that burns no fossil fuel for heat, ventilation or hot water and sits away from any combustion source (§ 56-170B(1)), and a steam, hot-water or electric-heated unit with no duct or shaft connection to a fossil-fuel boiler or heater (§ 56-170B(2)).

Every other unit needs at least one detector within 10 feet of each sleeping room (§ 56-170C), plus an additional detector in any unit attached to or above a garage (§ 56-170D). Hotels and motels need one detector per 10,000 square feet of floor area on any floor with a fossil-fuel appliance, boiler, furnace or warm-air heating (§ 56-170E). Every detector must meet UL 2034-96 Second Edition and carry a digital CO readout (§ 56-170G). Section 56-171 splits maintenance duties: the owner installs the initial units, replaces any device that fails within a year due to a manufacturing defect within 30 days of written notice, and replaces batteries before re-renting a vacated unit; tenants test, maintain and replace batteries in their own units.

Buildings heated by one central fossil-fuel unit get a second layer under § 56-172: a detector in the room housing the heating unit, in any adjacent or overhead room, and in corridors leading to the heater room. Removing batteries or otherwise disabling a required detector is unlawful under § 56-170I, except for routine battery replacement.

Violations & Fines

Under § 56-173, any violation of this article is an enhanced Class II offense as defined in § 56-11: a criminal fine of $200 to $1,000 and up to 15 days in jail, or a civil penalty of $500 to $7,500, and the Building Commissioner can pursue either track. Owners who fail to replace a defective detector within 30 days of written notice face the same enhanced penalty.

Frequently Asked Questions

Do all Yonkers apartments need carbon monoxide detectors?
Yes, unless the unit burns no fossil fuel and sits away from any combustion source, or is electrically or steam heated with no duct connection to a fossil-fuel boiler under § 56-170B. Nearly every occupied residential unit in the city must have at least one detector.
Who replaces batteries in a Yonkers rental's CO detector?
The owner replaces the battery whenever a tenant vacates, before the next tenant moves in, per § 56-171C. Otherwise, the tenant tests, maintains and replaces batteries during their own tenancy under § 56-171B.
Can I remove the batteries from my carbon monoxide detector?
No. Section 56-170I makes it unlawful to remove batteries or otherwise disable a required detector, except when a building owner, manager or agent is performing a normal battery replacement.
What happens if my landlord ignores a broken detector?
If a detector fails within a year of installation due to a manufacturing defect, § 56-171A(1) requires the owner to replace it within 30 days of written notice; failing to do so is an enhanced Class II offense under § 56-173.

Sources & Official References

Other rules in Yonkers

All Yonkers rules

New York rules heatmap·Compare Yonkers to another location·View the New York building safety overview

Get notified when Carbon Monoxide Detectors in Yonkers, NY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Carbon Monoxide Detectors in Nearby Cities

How other cities in Westchester County handle carbon monoxide detectors.

Mount Vernon, NY
Some Restrictions