Ankeny, IA Building Safety: Door Locking Hardware (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Rule
Thumb turn locks not allowed
IBC section amended
1010.2.2, Chapter 10 means of egress
Local section
Ankeny Building Code § 175.44
Compliance check
Building Official inspection before covering work
Appeals body
Ankeny Board of Examiners and Appeals

Summary

Ankeny's Building Code amendment to IBC Section 1010.2.2 flatly bars thumb turn locks on doors covered by the means-of-egress hardware rules in Chapter 10, closing off a lock style that can trap occupants trying to exit quickly during a fire or other emergency.

Section 1010.2.2 is hereby amended by adding a new sentence following this section: Section 1010.2.2 Hardware. Thumb turn locks shall not be allowed.

Full Breakdown

Ankeny Code of Ordinances Section 175.44 adds a sentence to IBC Section 1010.2.2, which sits in Chapter 10, Means of Egress, and governs the hardware allowed on egress doors, stating simply that thumb turn locks shall not be allowed. It is one of several local tightenings of the same egress chapter: Section 175.42 requires exterior walking surfaces at exits be concrete, asphalt or another approved hard surface, Section 175.43 narrows the two-way communication exception for certain two-story elevators, and Section 175.45 tightens the handrail exception for interior stairs of four or more risers in Group R-2 and R-3 units.

Section 1010.2.2 hardware requirements exist so that people can operate an egress door without special knowledge, a key, or unusual effort, and a thumb turn lock can be harder to release quickly or can be left engaged by mistake, defeating that purpose. Compliance is checked at the Building Official's required inspections before work can be covered or approved under Section 175.13, and appeals over hardware calls go to the Ankeny Board of Examiners and Appeals created under Section 175.21 instead of the standard IBC appeals board.

Violations & Fines

Installing or leaving in place a thumb turn lock on hardware covered by Section 1010.2.2 is a building code violation; the Building Official can withhold inspection approval or a Certificate of Occupancy until the noncompliant hardware is replaced, and the violation is separately enforceable as a municipal infraction under Chapter 4, carrying a civil penalty of up to $750 for a first offense and up to $1,000 for each repeat day.

Frequently Asked Questions

Are thumb turn locks legal on doors in Ankeny?
No. Section 175.44 amends IBC Section 1010.2.2 to add a flat rule that thumb turn locks shall not be allowed, covering the door hardware requirements that apply to means-of-egress doors under Chapter 10 of the Ankeny Building Code.
Why does Ankeny ban this type of lock?
Section 1010.2.2 sits within the IBC's means-of-egress hardware rules, which require egress doors to be operable without special knowledge or unusual effort so occupants can get out quickly in an emergency; Ankeny's added sentence closes off a lock style that can be slower to release or accidentally left engaged.
Who decides if my door hardware complies?
The Building Official reviews hardware at required inspections before work can be covered or approved, per Section 175.13, and disputes go to the Ankeny Board of Examiners and Appeals created under Section 175.21 in place of the standard IBC appeals process.

Sources & Official References

Other rules in Ankeny

All Ankeny rules

Compare Ankeny to another location·View the Iowa building safety overview

Get notified when Door Locking Hardware in Ankeny, IA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.