Parker, CO Building Safety: Electrical Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted code
NFPA 70, 2023 Edition
Citation
PMC § 11.05.020
15-amp circuit cap
10 outlet openings
20-amp circuit cap
13 outlet openings
Max fine
$499 per violation

Summary

The Town of Parker enforces electrical work through the 2023 National Electrical Code, adopted by reference as the Parker Electrical Code. Parker Municipal Code § 11.05.020 adopts NFPA 70 in full, and local amendments in Section 11.05.050 add Town-specific wiring and receptacle rules on top of the model code.

Pursuant to Title 31, Article 16, Part 2, C.R.S., the NFPA 70, National Electrical Code, 2023 Edition, as published by the National Fire Protection Association, One Batterymarch Park, Quincy, MA 02169-7471, is hereby adopted by reference and incorporated into this Chapter as though fully set forth herein. Except as otherwise provided hereafter, such code is adopted in full, including the outline of contents, index and appendices contained therein. ... In addition to the penalty provisions contained in the Code, any person who violates any of the provisions of this Chapter shall be guilty of a misdemeanor and, upon conviction thereof, shall be fined the sum of not more than four hundred ninety-nine dollars ($499.00) for each such violation. Each day that a violation continues after due notice has been served shall be deemed a separate offense.

Full Breakdown

Chapter 11.05 of the Parker Municipal Code, the Parker Electrical Code, adopts NFPA 70, the National Electrical Code, 2023 Edition, by reference under Section 11.05.020, citing Title 31, Article 16, Part 2, C.R.S. as the Town's statutory authority to regulate electrical work. The Town Council adopts the model code in full, including its outline of contents, index and appendices, then layers on local amendments in Section 11.05.050. Those amendments include a stricter definition of a dry electrical location that requires exterior openings to be sealed and roofing complete or sealed to the Building Official's satisfaction, a cap of ten outlet openings on a 15-amp branch circuit and thirteen on a 20-amp circuit in dwelling units, and a kitchen counter receptacle rule requiring at least two small-appliance branch circuits with no more than four outlet openings each.

The amendments also set service disconnect height limits, generally between 3 feet 6 inches and 6 feet 7 inches above grade, with a wider range allowed for tiered metering on multifamily buildings. Electrical contractors must register with the Town's Building Department, and the Chapter 11.19 registration rules bar the Town from issuing an electrical permit unless the contractor's current Colorado state electrical license is verified and on file, since electrical contractors are licensed by the State under Section 12-23-105, C.R.S. and only need to register locally.

Violations & Fines

Performing electrical work in Parker without a registered, state-licensed contractor pulling the required permit, or in a way that does not meet the 2023 NEC as amended, violates Chapter 11.05. Section 11.05.060 makes any violation a misdemeanor punishable by a fine of up to $499 per offense, with each day a violation continues after notice deemed a separate offense.

Frequently Asked Questions

What electrical code does Parker use?
The 2023 edition of NFPA 70, the National Electrical Code, adopted by reference as the Parker Electrical Code under Parker Municipal Code § 11.05.020, with Town-specific amendments layered on in Section 11.05.050.
Do electricians need a Town permit for wiring work?
Yes. Chapter 11.19's contractor registration rules require a current, state-verified electrical license on file with the Building Department, and no permit for electrical wiring may issue to an applicant whose state license has not been verified and registered.
How many outlets can share one circuit in a Parker home?
Ten outlet openings on a 15-amp branch circuit and thirteen on a 20-amp circuit, under the local amendment to NEC Article 210.23(B) in Parker Municipal Code § 11.05.050(2), with fixed lighting counted at 180 watts per outlet opening.

Sources & Official References

Other rules in Parker

All Parker rules

Compare Parker to another location·View the Colorado building safety overview

Get notified when Electrical Permits in Parker, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.