Prescott Valley, AZ Building Safety: Electrical Permits (2026)
Key Facts
- Adopted code
- 2017 National Electrical Code, § 7-05-005
- Administration
- Article 7-01, enforced through the building official, § 7-05-007
- Existing wiring
- Additions or alterations first approved by building official, § 7-05-010
- Tamper-resistant receptacles
- Not required in detached one and two-family dwelling units
- Panels
- Separate distribution panel for each store, apartment or dwelling
- Criminal penalty
- Class 1 misdemeanor, fine up to $2,500, up to six months
Summary
In the Town of Prescott Valley, Arizona, all electrical work must follow the 2017 National Electrical Code as amended by Town Code Article 7-05, plus the rules set by the building official. Section 7-05-005 adopts the NEC and § 7-05-007 routes administration and enforcement to Article 7-01. Permits come from the building official under § 7-01-140.
The National Electrical Code (NEC), 2017 Edition, as copyrighted by the National Fire Protection Association, Inc., with amendments contained in this document, is hereby adopted by reference as though fully set forth herein, as one of the technical codes of the Town of Prescott Valley. At least three (3) copies of the aforesaid NEC shall be filed in the Office of the Town Clerk and made available for public use and inspection. ... Any and all electrical work for light, heat, power or any other purpose shall be installed in conformity with the rules and regulations as set forth in that document titled the National Electrical Code, 2017 Edition, as amended herein, and in conformity with the rules and regulations set forth by the building official. ... This National Electrical Code shall be administered and enforced pursuant to Article 7-01, THE TOWN OF PRESCOTT VALLEY ADMINISTRATIVE CODE, in Chapter 7, BUILDING, of the Prescott Valley Town Code.
Full Breakdown
Section 7-05-005 adopts the National Electrical Code (NEC), 2017 Edition, "as one of the technical codes of the Town of Prescott Valley," with at least three copies on file in the Office of the Town Clerk for public inspection. Section 7-05-007 adds to NEC Article 90 that all electrical work for light, heat, power or any other purpose must conform to the 2017 NEC as amended and to the rules set by the building official, and that the code is administered and enforced under Article 7-01 of the Town Code.
The Town then amends specific NEC provisions. Section 7-05-010 rewrites NEC 110.8 so that, for existing or relocated buildings, the NEC applies where the building official deems the wiring methods inadequate or unsafe; relocated buildings must have service equipment that conforms to NEC Article 230; and additions to or alterations in existing wiring must first be approved by the building official. Section 7-05-040 deletes NEC 406.4(D)(5), adds an exception to 406.12 so tamper-resistant receptacles are not required in detached one and two-family dwelling units, and adds to NEC 408.30 a rule that each separate store, apartment or dwelling has its own lighting and power distribution panels, while hotels, motels and similar buildings can be wired from one or more distribution panels.
Permits sit in § 7-01-140. Subsection (F) lists the electrical work that needs no electrical permit, such as portable motors with an attachment plug, listed cord and plug temporary decorative lighting, repair or replacement of an overcurrent device of the required capacity in the same location, and wiring operating at less than 25 volts that cannot supply more than 50 watts. Work exempt from a building permit still needs a separate electrical permit unless otherwise exempted. Applications follow § 7-01-150, and work must stay exposed for inspection under § 7-01-180, where the building official can require that an inspection request be filed at least one working day ahead, including through the Selectron Inspection Request System.
Violations & Fines
Violating any provision of Chapter 7 of the Town Code is a class 1 misdemeanor under § 7-01-130(A), punishable by a fine not to exceed $2,500, imprisonment not to exceed six months, or both, and each day is a separate offense. The civil route in § 7-01-130(B) carries a sanction not to exceed $250 per citation under Article 1-08. Paying a penalty does not relieve the violator of correcting the work, and the Town can seek an injunction or abatement.
Frequently Asked Questions
Which edition of the NEC does Prescott Valley enforce?
Can I add a circuit to existing wiring without approval?
Does replacing a receptacle need an electrical permit?
Are tamper-resistant receptacles required in new houses?
How do I request an electrical inspection?
Sources & Official References
Other rules in Prescott Valley
Compare Prescott Valley to another location·View the Arizona building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Electrical Permits in Nearby Cities
How other cities in Yavapai County handle electrical permits.