Jackson, TN Building Safety: Fire Sprinkler Requirements (2026)
Key Facts
- Applies to
- Group R-2 apartments up to 5 stories
- Sprinkler requirement
- Throughout, per § 903.3.1.1 (§ 12-204)
- Sprinkler type
- Residential-type in every dwelling unit
- Density limit
- Max 4 dwelling units per floor
- Travel distance
- 125-foot maximum to exit stairway
- Adopted
- Ordinance #2025-15, January 2025
Summary
Jackson Municipal Code § 12-204, adopted by Ordinance #2025-15 in January 2025, amends the 2018 International Building Code's Section 1006.3.3 so that a Group R-2 apartment building of up to five stories served by a single exit stairway must be sprinklered throughout, with residential-type sprinklers in every dwelling unit's habitable spaces.
Section 1006.3.3 of the 2018 Edition of the International Building Code is hereby amended by adding a new condition 6 as follows: 6.Not more than five stories of Group R-2 Occupancy are permitted to be served by a single exit under the following conditions:6.1The building has not more than six stories above grade plane. ... 6.4.The building shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. Residential-type sprinklers shall be used in all habitable spaces in each dwelling unit.
Full Breakdown
Section 12-204 of the Jackson Municipal Code, added by Ordinance #2025-15 in January 2025, creates a new "Condition 6" inside Section 1006.3.3 of the locally adopted 2018 International Building Code, governing when a Group R-2 apartment building, meaning multifamily residential occupancy, may rely on a single exit stairway instead of the two exits the IBC generally requires. Condition 6 allows up to five stories of Group R-2 occupancy on a single exit only if the building is no taller than six stories above grade, is not a boarding house or used for transient occupants, and has no more than four dwelling units per floor.
Critically for fire protection, subsection 6.4 mandates that the building be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, and further specifies that residential-type sprinklers be used in all habitable spaces in each dwelling unit, making sprinkler coverage a non-negotiable trade-off for the single-stair design. The amendment pairs the sprinkler mandate with other life-safety conditions: a maximum of two single-exit-stairway conditions per property separated by two-hour fire-rated walls, a pressurized interior exit stairway, self-closing sixty-minute fire-rated dwelling unit doors, a travel distance cap of 125 feet to the exit, and restrictions on what other occupancies may share the building.
Compliance is reviewed by the Building and Housing Codes Department established under § 12-102 as part of plan review and inspection for any qualifying apartment project.
Violations & Fines
Because § 12-204 operates inside the adopted 2018 International Building Code, a building that uses the single-exit-stairway allowance without meeting every Condition 6 requirement, including the automatic sprinkler system in Section 903.3.1.1, fails building code plan review by the Building and Housing Codes Department and cannot receive a certificate of occupancy; unresolved violations otherwise fall to the general penalty provision, § 3-102, up to five hundred dollars ($500.00) plus costs.
Frequently Asked Questions
Does Jackson require sprinklers in apartment buildings?
How tall can a single-exit apartment building be in Jackson, TN?
When did Jackson add this sprinkler condition to its building code?
Sources & Official References
Other rules in Jackson
Compare Jackson to another location·View the Tennessee building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.