Lehi, UT Building Safety: Fire Sprinkler Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Trigger
Any 1 of 6 conditions in §10-3-1
Water flow
500-1,000 gpm by home size
Access road
>10% grade over 500 ft triggers rule
Adopted
Ord. 06-08-10.4, June 8, 2010
Note
Separate from Dry Creek WUI mandate

Summary

City Code section 10-3-1 requires an automatic fire sprinkler system in new homes built under the International Residential Code when any one of six conditions is met, from a wildland-urban interface location to inadequate water flow or a steep fire-access road. It applies in addition to, not instead of, the separate WUI Code sprinkler mandate for the Dry Creek Corridor.

The city hereby finds and determines that under certain conditions, an automatic fire sprinkler system shall be installed in structures built in accordance with the requirements of the international residential code, as adopted in the state construction code, when any of the following subsections apply: ... D. ... The water supply to the structure does not provide at least five hundred (500) gallons' fire flow per minute for a minimum of thirty (30) minutes, if the total square foot living space of the structure is equal to or less than five thousand (5,000) square feet.

Full Breakdown

City Code section 10-3-1 finds that an automatic fire sprinkler system must be installed in structures built under the International Residential Code, as adopted in the state construction code, whenever any of six conditions applies. Condition A is location in an urban wildland interface area under the Utah Wildland Urban Interface Code that does not meet the minimum standards in Utah Code section 65A-8-203(3)(a) and Utah Administrative Code rule R652-122-200. Condition B is an area lacking a public water distribution system with fire hydrants meeting Utah Administrative Code rule R309-550-5.

Condition C is a fire apparatus access road with a grade over ten percent for more than five hundred continuous feet. Conditions D, E and F set minimum fire flow by house size: at least 500 gallons per minute for thirty minutes for homes up to 5,000 square feet, 750 gallons per minute for homes between 5,000 and 10,000 square feet, and 1,000 gallons per minute for homes over 10,000 square feet. 1 amendment in section 10-2-1(E), which independently requires sprinklers in new Dry Creek Corridor buildings needing Class 1 or Class 2 ignition-resistant construction; a home in that corridor can trigger both requirements at once.

Violations & Fines

Section 10-3-1 carries no penalty clause of its own, so noncompliance is enforced through the building permit and inspection process under Chapter 2: the Assistant Building Official can withhold final inspection approval and occupancy until a required sprinkler system is installed, and unpermitted work otherwise falls under the citywide general penalty at section 1-4-1, up to the maximum class B misdemeanor fine under Utah Code 76-3-301.

Frequently Asked Questions

Does Lehi require fire sprinklers in new homes?
Yes, if any of six conditions in City Code section 10-3-1 applies, including being in a wildland interface area, lacking hydrant water service, a steep-grade access road, or inadequate fire flow for the home's size.
How much water flow does Lehi require to avoid a sprinkler mandate?
Section 10-3-1 sets minimums by size: 500 gallons per minute for thirty minutes for homes up to 5,000 square feet, 750 gpm for 5,000 to 10,000 square foot homes, and 1,000 gpm for larger homes.
Is the Dry Creek Corridor sprinkler rule the same as section 10-3-1?
No. Section 10-3-1 is a citywide rule triggered by water, access-road or wildland conditions, while the Wildland-Urban Interface Code's Section 602.1 amendment separately mandates sprinklers for qualifying new buildings throughout the Dry Creek Corridor.
What access road condition triggers the sprinkler requirement?
Under section 10-3-1(C), if the only fire apparatus access road has a grade over ten percent for more than five hundred continuous feet, an automatic sprinkler system is required.

Sources & Official References

Other rules in Lehi

All Lehi rules

Compare Lehi to another location·View the Utah building safety overview

Get notified when Fire Sprinkler Requirements in Lehi, UT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.