Bossier City, LA Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- R-A/R-E/R-MD height limit
- 3 stories or 45 ft.
- R-LD height limit
- 2 stories or 35 ft.
- R-HD height limit
- 6 stories or 90 ft.
- Manufactured housing districts
- Flat 35 ft. limit
- R-LD height bonus
- To 45 ft. by adding yard depth
Summary
Bossier City caps residential building height by zoning district in UDC Section 6.5. R-A, R-E and R-MD lots max out at 3 stories or 45 feet, R-LD is limited to 2 stories or 35 feet, and R-HD allows up to 6 stories or 90 feet, whichever measure is lower in each case.
Sec. 6.5 - Height Restrictions. Except as provided in Section 15.3, all structures shall comply with the height requirements specified in the following table: District Maximum Height R- ... A Residence-Agriculture 3 stories or 45 ft., whichever is less R-E Residential Estate 3 stories or 45 ft., whichever is less R-LD Residential, Low Density 2 stories or 35 ft., whichever is less 1 R-MD Residential, Medium Density 3 stories or 45 ft., whichever is less R-HD Residential, High Density 6 stories or 90 ft., whichever is less R-MHP Residential, Manufactured Housing Park and R-MHS; Residential Manufactured Housing Subdivision 35 feet ... 1. Maximum height in the R-LD district may be increased to 45 ft., provided that each side and rear yard minimums are increased by 1 foot for each additional foot of height above 35 ft.
Official source re-checked November 3, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 23).
Full Breakdown
Section 6.5 of the Unified Development Code requires "all structures... comply with the height requirements specified in the following table," except as Section 15.3 provides otherwise. R-A Residence-Agriculture, R-E Residential Estate and R-MD Medium Density each cap out at "3 stories or 45 ft., whichever is less." R-LD Low Density is held to "2 stories or 35 ft., whichever is less," the tightest residential limit in the table, while R-HD High Density permits up to "6 stories or 90 ft., whichever is less," by far the tallest residential allowance in the city.
Manufactured housing districts (R-MHP and R-MHS) are capped flatly at 35 feet with no story count. A footnote lets the R-LD maximum rise to 45 feet, but only if the owner gives up yard space: "each side and rear yard minimums are increased by 1 foot for each additional foot of height above 35 ft.," trading setback space for extra height rather than granting it for free. Commercial districts generally sit at 2 stories or 35 feet, lower than R-HD's residential allowance, except B-4 Downtown Business at a flat 35 feet with a two-story minimum facade requirement on structures fronting Barksdale Boulevard.
Violations & Fines
Constructing a structure taller than the district's height limit, or above the R-LD trade-off cap without the matching yard increase, is a UDC Section 17.7.1 misdemeanor: a fine up to $500, up to 30 days in jail, or both, set by the court, with each day of continued violation a separate offense, and the Executive Director can issue a stop order under Section 17.3.2.
Frequently Asked Questions
How tall can a house be in R-LD zoning?
What's the tallest residential building allowed in Bossier City?
Is there a height limit for manufactured homes?
Sources & Official References
Other rules in Bossier City
Compare Bossier City to another location·View the Louisiana building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.