Bossier City, LA Parking Rules: Loading Zones (2026)
Key Facts
- Governing section
- UDC § 12.5.7, Off-Street Loading Schedule
- Small space minimum
- 10 ft clearance, 8 ft wide, 20 ft long
- Large space minimum
- 14 ft clearance, 12 ft wide, 50 ft long
- Loading-space threshold
- Required once gross floor area exceeds 5,000 sq ft
- Right-of-way rule
- No loading/unloading from collector or arterial ROW
- Reviewing agency
- City or Parish Engineer
Summary
Bossier City requires off-street loading spaces sized by building floor area under Unified Development Code Section 12.5.7, and bars loading or unloading from the right-of-way of any collector or arterial street. Buildings under 5,000 square feet need none; larger buildings must provide small or large spaces per Table 12.5.7, reviewed by the City or Parish Engineer.
12.5.7Off-Street Loading Schedule.A.Goods may not be loaded or unloaded from the right-of-way of a collector or arterial street and no part of any vehicle may extend into the right-of-way of a collector or arterial street while being loaded or unloaded.B.If required by the City or Parish Engineers, off-street loading spaces must be provided in accordance with the minimum requirements enumerated in Table 12.5.7. ... Gross floor area (sq. ft.) Required spaces 0 to 5,000 none 5,000 to 12,500 1 small 12,501 to 25,000 2 small 25,001 to 40,000 1 large 40,001 to 100,000 2 large Each additional 80,000 over 100,000 1 large C.Off-street loading spaces are defined as follows:1.Small spaces must have a minimum vertical clearance of 10 feet, minimum width of 8 feet, and minimum length of 20 feet.2.Large spaces must have a minimum vertical clearance of 14 feet, minimum width of 12 feet, and minimum length of 50 feet.
Full Breakdown
Section 12.5.7 of the Unified Development Code splits the loading rule in two. Subsection A is an absolute prohibition: goods cannot be loaded or unloaded from the right-of-way of a collector or arterial street, and no part of any vehicle may extend into that right-of-way during loading or unloading, regardless of the site's parking layout. Subsection B ties the number of required off-street loading spaces to a building's gross floor area through Table 12.5.7: buildings of 5,000 square feet or less need none, 5,000 to 12,500 square feet need one small space, 12,501 to 25,000 square feet need two small spaces, 25,001 to 40,000 square feet need one large space, 40,001 to 100,000 square feet need two large spaces, and every additional 80,000 square feet above 100,000 adds one more large space.
Subsection C defines the spaces themselves: a small space needs a minimum 10-foot vertical clearance, 8-foot width and 20-foot length, while a large space needs 14 feet of clearance, 12 feet of width and 50 feet of length; neither figure counts the maneuvering or access area feeding the space. The City or Parish Engineer reviews these calculations as part of the off-street parking and loading review that every nonresidential site plan must pass before a building permit or certificate of occupancy is issued.
Violations & Fines
The City or Parish Engineer enforces Section 12.5.7 during site plan review, and a project that omits the small or large spaces Table 12.5.7 requires for its floor area cannot receive plan approval or a building permit. Loading or unloading from within the right-of-way of a collector or arterial street, or letting any part of a vehicle extend into that right-of-way while loading, breaches Section 12.5.7.A outright, even on a site whose plan was already approved.
Frequently Asked Questions
Does every business in Bossier City need an off-street loading space?
Can a delivery truck stop in the street to unload in Bossier City?
How big does a large loading space have to be?