Broomfield, CO Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- Max height
- 30 feet
- Max stories
- two
- Same cap in
- A-1, E-1, E-2 districts
- RR/E-3 cap
- 33 feet
- Minimum lot area
- 7,000 sq ft
- Front yard
- 25 feet
Summary
Broomfield caps buildings in the R-1 Low-Density Residential District at two stories and thirty feet under section 17-14-050, the standard height ceiling for the city's average-lot single-family zone alongside the A-1, E-1, and E-2 districts, which share the same two-story, thirty-foot maximum.
17-14-050 - Building height. Buildings in the R-1 district shall not be higher than two stories, and in no case higher than thirty feet.
Full Breakdown
Section 17-14-050 sets the R-1 height ceiling at two stories and, in no case, higher than thirty feet. R-1 is the district described in section 17-14-010 for areas where standard housing concepts are proposed on average-sized lots, and it permits one-family dwellings, public and private schools, churches, public recreation areas, and home occupations under section 17-32-020 by right under section 17-14-020. The same two-story, thirty-foot cap applies in the A-1 Agricultural District (section 17-08-050), the E-1 Estate District (section 17-10-050), and the E-2 Estate District (section 17-12-050), while the RR Rural Residential and E-3 Estate Districts allow a taller 33-foot maximum measured under section 17-38-320(F).
Section 17-14-040 pairs the height limit with dimensional standards: a 7,000-square-foot minimum lot (70 feet wide on an interior lot, 80 feet on a corner lot), a 25-foot front yard, a 25-foot rear yard for the principal building, and side yards of 5 feet each, with a combined minimum of 15 feet between the two sides. Section 17-14-060 folds in the parking, sign, and other general provisions of Title 17. Any development seeking to exceed the thirty-foot cap in R-1 would need a rezoning or a planned unit development, since section 17-14-050 sets the limit as an absolute ceiling rather than a variance-eligible standard.
Violations & Fines
The building official enforces the height cap through chapter 17-50: an oversized structure can be ordered corrected under section 17-50-040, and failure to comply within ten days is a misdemeanor under section 17-50-050. Section 17-50-070 applies the chapter 1-12 general penalty, up to a $2,650 fine or 364 days in jail, with each day of noncompliance a separate offense.
Frequently Asked Questions
How tall can a house be in Broomfield's R-1 district?
Can I get a variance to build higher than 30 feet in R-1?
What lot size does Broomfield require in the R-1 district?
What is the penalty for building above the R-1 height limit?
Sources & Official References
Other rules in Broomfield
Compare Broomfield to another location·View the Colorado building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.