Building Setbacks & Zoning in Burleson, TX (2026)
3 verified building setbacks & zoning rules for Burleson, Texas, sourced directly from the municipal code and official government pages.
Verified from official government sources
Setback Rules
In the City of Burleson, Texas, the SF7 single-family district requires a 25 feet minimum front yard, a ten feet minimum rear yard and a five feet minimum side yard, with 15 feet minimum on the side adjacent to a side street. Other districts set their own minimums in Appendix B, and § 132 adds yard rules that apply in all zoning districts.
Yard Setback Minimums in Burleson Zoning Districts
Some RestrictionsBurleson Code of Ordinances, App. B, § 57-120
Development area regulations.In the SF7, single-family dwelling district-7, the following regulations apply to all uses: See section 132, general yard requirements for general information regarding yard requirements. ... (d) Depth of front yard: 25 feet minimum. (e) Depth of rear yard: ten feet minimum. (f) Width of side yard: five feet minimum (see section 132 general, yard requirements). (g) ...
Structure Height Limits
In the City of Burleson, Texas, the SFE, SF16, SF10, SF7 and SFA single-family districts limit buildings to 2½ stories, the 2F two-family district to two stories, and the A agricultural district to three stories. Section 133 sets the exceptions, including chimneys and roof gables that can add height not to exceed 40 feet above the average grade line.
Burleson Residential Building Height Limits
Some RestrictionsBurleson Code of Ordinances, Zoning Ordinance §§ 57-115, 133-100
Height requirements.No building shall exceed 2½ stories except as permitted by section 133, general height requirements. ... Generally.The following height requirements shall apply: (a) Cooling towers, roof gables, chimneys, and vent stacks may extend for an additional height not to exceed 40 feet above the average grade line of a building. Water standpipes and tanks, religious institution stee...
Lot Coverage Limits
In the City of Burleson, Texas, multi-family development carries two building coverage caps: the main building can cover 40% of the lot area, and the main building plus all accessory buildings can cover 50%. The same section sets a 2 acre minimum lot and density limits of 12 units per acre in MF1 and 24 in MF2.
Burleson Multi-Family Building Coverage Limits
Some RestrictionsBurleson Code of Ordinances, Appendix C, Art. VIII, § 8-40
Area regulations: The following regulations apply to all uses. See Sec. 132. General Yard Requirements for general information regarding yard requirements. (a) Lot size 2 acres minimum (b) Density MF1 - 12 units per acre maximum MF2 - 24 units per acre maximum (c) Building coverage Maximum coverage of the main building is 40% of the lot area. Maximum coverage of the main building and all access...