Elevator Maintenance
In the City of Burleson, Texas, § 10-142 amends the elevator chapter of the 2021 International Building Code. Storage is not allowed in an elevator machine room, control room, machinery space or control space, and each entry needs approved signage stating "No Storage Allowed." Sprinklers are prohibited in machine rooms and hoistways, and the shunt trip is omitted.
Burleson Elevator Machine Room and Hoistway Rules
Some RestrictionsBurleson Code of Ordinances § 10-142
Section 3002.1 Hoistway Enclosure Protection; add exceptions to read as follows: Exceptions: 1. Elevators wholely located within atriums shall not require hoistway enclosure protection. 2. Elevators in open or enclosed parking garages that serve only the parking garage, and complying with Sections 406.5 and 406.6, respectively, shall not require hoistway enclosure protection. ... 3005.5.1.1.1 P...
Fire Sprinkler Requirements
In the City of Burleson, Texas, § 10-172 amends Section R313.2 of the 2021 International Residential Code to say an automatic sprinkler system shall be installed in one- and two-family dwellings in accordance with the adopted Fire Code and the amendments thereto. The same section of the code deletes the townhouse sprinkler exception to Section R302.2.6.
Burleson One- and Two-Family Dwelling Sprinkler Rule
Significant RestrictionsBurleson Code of Ordinances § 10-172
Section R302.2.6; delete exception #6: Exceptions: {previous exceptions unchanged} 6. Townhouse units protected by a fire sprinkler system complying with Section P2904 or NFPA 13D. ... Section R313.2 Automatic Fire Sprinkler Systems. Amend to read as follows: R313.2 One- and Two-Family dwellings automatic sprinkler systems. An automatic sprinkler system shall be installed in one- and two-family...
Childcare Center Rules
In the City of Burleson, Texas, § 10-142 requires an approved smoke detection system in Group E day care occupancies. A residential in-home day care with not more than 12 children can use interconnected single station detectors in all habitable rooms. Under § 10-492, childcare centers cannot have ladders of any type on fire escapes used as a required means of egress.
Burleson Day Care Fire Alarm and Fire Escape Rules
Some RestrictionsBurleson Code of Ordinances § 10-142
[F] 907.2.3 Group E. A manual fire alarm system that initiates the occupant notification signal utilizing an emergency voice/alarm communication system meeting the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shal...
Door Locking Hardware
In the City of Burleson, Texas, § 10-142 amends Section 1010.2.5 (Bolt Locks) of the 2021 International Building Code by rewriting exceptions 3 and 4. Exception 3 covers a pair of doors serving an occupant load of less than 50 persons in a Group B, F, M or S occupancy. Exception 4 covers a pair of doors serving a Group A, B, F, M or S occupancy.
Burleson Bolt Lock Exceptions for Pairs of Doors
Some RestrictionsBurleson Code of Ordinances § 10-142
Section 1010.2.5 Bolt Locks; amend exceptions 3 and 4 as follows: Exceptions: 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F, M or S occupancy. {Remainder unchanged} 4. Where a pair of doors serves a Group A, B, F, M or S occupancy {Remainder unchanged}
Green Building Code
The City of Burleson, Texas adopts the 2021 edition of the International Energy Conservation Code as the energy conservation code of the city in § 10-351, with local amendments in § 10-352. Each 1- and 2-family dwelling is tested for air and duct leakage, and Energy Star certification of energy code equivalency counts as compliance.
Burleson 2021 Energy Conservation Code Adoption
Some RestrictionsBurleson Code of Ordinances § 10-351
The 2021 edition of the International Energy Conservation Code of the International Code Council, as hereinafter amended, is from the effective date hereof herby adopted as the energy conservation code of the city. One copy of such International Energy Conservation Code is incorporated herein by reference and shall have been filed for permanent record and inspection in the office of the city se...
Carbon Monoxide Detectors
In the City of Burleson, Texas, every permitted short-term rental must have working smoke and carbon monoxide detectors with alarms, installed in accordance with adopted codes, and at least one working type A fire extinguisher. The carbon monoxide requirement printed in the city code applies to short-term rentals.
Burleson TX Short-Term Rental CO Detector Rule
Some RestrictionsBurleson Code of Ordinances § 14-580(a)
(a) Smoke alarms and fire extinguisher.Each short-term rental owner or operator shall provide in the short-term rental working smoke and carbon monoxide detectors, with alarms, in accordance with adopted codes, and at least one working type A fire extinguisher. The owner or operator is responsible for obtaining annual independent inspections of the fire extinguishers in compliance with the city...
Building Permits
In the City of Burleson, Texas, the building official in the Building Permits and Inspections Department enforces the adopted 2021 International Building Code. Section 10-142 rewrites the Section 105.2 list under Building, including one story sheds and similar uses with a floor area not exceeding 120 square feet.
Burleson Building Permit Rules and IBC 105.2 Amendment
Some RestrictionsBurleson Code of Ordinances § 10-142
103.1 Creation of enforcement agency. The Department of Building Permits and Inspections Department is hereby created and the official in charge thereof shall be known as the building official. ... Section 105.2; under sub-title entitled "Building" amend, delete and re-number as follows: Building: 1. One story detached accessory structures used as tool and storage sheds, Playhouses and similar ...
Electrical Permits
In the City of Burleson, Texas, no one can obtain electrical permits or do electrical work without the appropriate level of city electrical licensing, except a helper or apprentice under a license holder's direct supervision. The city has adopted the 2020 edition of the National Electric Code as its electrical code.
Burleson Electrical License Rule and Adopted NEC
Significant RestrictionsBurleson Code of Ordinances §§ 10-101, 10-102(a), 10-201
No person shall obtain electrical permits or engage in electrical work without first possessing the appropriate level of city electrical licensing except that a helper or apprentice may perform work without being licensed, if such work is performed under the direct supervision of a valid license holder. ... (a) Master electrician license.A master electrician's license shall entitle the holder t...
Plumbing Permits
In the City of Burleson, Texas, no contractor can obtain a plumbing permit without first registering with the city. To qualify, a plumbing contractor must hold or employ at least one person with a valid state master plumber's license. Registration costs nothing, expires on December 31 and is renewed annually on or before February 1.
Burleson Plumbing Permit and Contractor Registration
Significant RestrictionsBurleson Code of Ordinances § 10-104
(a) Registration required.No contractor shall obtain any building, plumbing, mechanical or electrical permit without first registering with the city as a building, plumbing, mechanical or electrical contractor. ... (2) Plumbing contractors.To be eligible for registration, a plumbing contractor must hold or employ at least one person holding a valid state master plumber's license, who shall not ...
Building Inspections
In the City of Burleson, Texas, § 10-352 sets the required inspections under the 2021 Energy Conservation Code: footing and foundation, framing and air barrier rough-in, insulation and fenestration rough-in, plumbing rough-in, mechanical rough-in and a final inspection. A building shall not be occupied until the final inspection approves it.
Burleson Energy Code Inspection Stages and Re-Inspection Fees
Some RestrictionsBurleson Code of Ordinances § 10-352
Section 105.2 Required Inspections; Changed numbering and to read as follows: R105.2.1 Footing and foundation inspection. Inspections associated with footings and foundations shall verify compliance with the code as to R-value, location, thickness, depth of burial and protection of insulation as required by the code and approved plans and specifications. R105.2.2 Framing and Air Barrier rough-i...