Stormwater Management
In Seaside, land disturbance over 1000 square feet needs an approved Grading and Erosion Control Plan from the Department of Building and Code Enforcement, and the threshold drops to 500 square feet within 25 feet of a stream, watercourse or wetland. Storm sewer inlets and culverts must be protected, and stormwater cannot be sent to a sanitary sewer.
Seaside Stormwater, Erosion Control and Drainage Rules
Some RestrictionsSeaside Zoning Ordinance Art. 4, §§ 4.202(1), 4.204(2)(D), 4.204(4)
Except as otherwise provided in this ordinance, no person shall commence or perform any activities described in 4.202 a-c without receiving approval of a Grading and Erosion Control Plan by the City of Seaside Department Building and Code Enforcement. A. Any land disturbing activity (i.e. clearing, grading, stripping, excavation, fill, or any combination thereof) that will affect an area in exc...
Erosion Control
In Seaside, no one can start clearing, grading, stripping, excavation or fill above set thresholds without an approved Grading and Erosion Control Plan from the Department of Building and Code Enforcement. The triggers are 1000 square feet of disturbance, 500 square feet within 25 feet of a stream, watercourse or wetland, or 20 or 50 cubic yards of cut or fill.
Seaside Grading and Erosion Control Plan Requirements
Some RestrictionsSeaside Zoning Ordinance §§ 4.201, 4.202(1)
Section 4.201 Purpose: It is the objective of this ordinance to control activities that lead to soil erosion and sedimentation into watercourses, wetlands, riparian areas, public and private roadways caused by development activities, including clearing, grading, stripping, excavating, and filling of land. ... 1. Grading and Erosion Control Plan Required Except as otherwise provided in this ordi...
Flood Zones
Seaside requires a floodplain development permit before construction or development begins anywhere in a special flood hazard area, covering all structures, manufactured dwellings and other development including fill. Ordinance No. 2025-04 repealed and replaced Chapter 152, and a violation is a misdemeanor punishable by a fine of not more than $500.00, imprisonment up to 180 days, or both.
Seaside Floodplain Development Permits and Flood Hazard Rules
Significant RestrictionsSeaside Code of Ordinances §§ 152.3.2, 152.3.4.2, 152.4.3.1 (Ord. No. 2025-04)
The special flood hazard areas identified by the Federal Insurance Administrator in a scientific and engineering report entitled "The Flood Insurance Study (FIS) for Clatsop County Oregon and Incorporated Areas Volume 1 & 2 dated June 20, 2018, with accompanying Flood Insurance Rate Maps (FIRMs) are hereby adopted by reference and declared to be a part of this ordinance. ... shall constitute a ...
Boat Dock Permits
Seaside's Zoning Ordinance sets estuarine standards for docks and moorages in Section 6.153. Community docks rank above private ones, a private dock applicant must prove that marinas, community docks and mooring buoys are unavailable or impractical, and the dock must be the minimum size needed. Covered moorage is barred outside commercial or industrial use, and fill to create a dock is not permitted.
Seaside OR Dock and Moorage Standards
Significant RestrictionsSeaside Zoning Ordinance § 6.153
Section 6.153 Dock/Moorage 1. Community docks or moorages shall be given higher priority than private individual docks or moorages. 2. Where a private individual dock is proposed, the applicant must provide evidence that alternative moorage sites, such as nearby marinas, community docks or mooring buoys are not available, are impractical, or will not satisfy the need. 3. Evidence shall be provi...
Flood Elevation Requirements
In Seaside riverine flood zones, new residential construction and substantial improvements must have the lowest floor, including basement, elevated a minimum of one foot above the Base Flood Elevation. In coastal V and VE zones the bottom of the lowest horizontal structural member must sit a minimum of one foot above the base flood level. Riverine non-residential buildings can instead be floodproofed.
Seaside Flood Elevation Rules: One Foot Above Base Flood Elevation
Some RestrictionsSeaside Code of Ordinances §§ 152.5.2.3.2(A), 152.5.2.3.3(A)(1), 152.5.2.3.4(B), 152.5.3.1(A)(1) (Ord. No. 2025-04)
152.5.2.3.2 RESIDENTIAL CONSTRUCTION A. New construction, conversion to, and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated at a minimum of one (1) foot above the Base Flood Elevation (BFE). ... A. New construction, conversion to, and substantial improvement of any commercial, industrial, or other non-residential structure shall: 1...