Alexandria, VA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard requirement
- Base flood elevation + 1 foot
- Applies to
- New construction & substantial improvements in A/AE/AH zones
- Non-residential alternative
- Dry floodproofing with engineer certification
- Flood Design Class 4
- BFE+1ft or 0.2% chance elevation, whichever higher
- Mechanical equipment
- Must sit at/above BFE + 1 foot (§ 6-306(E))
Summary
Any new home or substantial improvement in Alexandria's mapped AE or AH flood zones must have its lowest floor, including the basement, elevated to at least one foot above the base flood elevation. Section 6-307(A) sets that one-foot freeboard for residential construction, and a matching standard applies to commercial and mixed-use buildings.
(A)Residential construction.(1)New construction or substantial improvement or any residential building or structure and their extensions and accessory buildings or structures in Zones A, AE, and with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood elevation plus 1-foot.(2)No building permit for the substantial improvement of an existing residential building shall be at least one foot issued unless the building has the lowest floor (including the basement) elevated to or above the base flood elevation plus 1-foot.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 156 | Zoning: Supplement 103).
Full Breakdown
Section 6-307 spells out the elevation math that applies once a parcel's base flood elevation (BFE) has been established from FEMA's Flood Insurance Study or a certified engineering analysis. Residential buildings, including additions and accessory structures, in Zones A, AE, and AH must have their lowest floor, basement included, elevated to or above the BFE plus one foot; no building permit for a substantial improvement of an existing home can issue unless that freeboard is met. Non-residential and mixed-use buildings face the same one-foot freeboard, but Section 6-307(B)(3) lets them dry-floodproof instead of elevating, provided a registered engineer or architect certifies the building is watertight below the BFE-plus-one-foot line and no floor below that line is used for human or animal habitation, food storage, or food preparation.
2-percent annual chance flood elevation. Mechanical, electrical, heating, and plumbing equipment must likewise sit at or above the base flood elevation plus one foot under Section 6-306(E), and any fully enclosed space left below that line can only be used for parking, building access, or storage, built from flood damage-resistant materials, with vents sized to at least one square inch per square foot of enclosed area.
Violations & Fines
Issuing or relying on a building permit without the required base-flood-elevation-plus-one-foot freeboard violates Section 6-307. Alexandria's floodplain administrator can withhold a certificate of occupancy, require an elevation certificate before final approval, and order retrofits, additional fill, or dry-floodproofing before a noncompliant structure may be occupied; the city also maintains elevation certifications on file as a condition of the property's ongoing eligibility in the National Flood Insurance Program.
Frequently Asked Questions
How high above the flood line must I build in Alexandria?
Can a commercial building in Alexandria's floodplain skip elevating?
Where do mechanical systems like furnaces have to sit?
Sources & Official References
Other rules in Alexandria
Compare Alexandria to another location·View the Virginia environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.