Skip to main content
CityRuleLookup

Alexandria, VA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
Base flood elevation + 1 foot
Applies to
New construction & substantial improvements in A/AE/AH zones
Non-residential alternative
Dry floodproofing with engineer certification
Flood Design Class 4
BFE+1ft or 0.2% chance elevation, whichever higher
Mechanical equipment
Must sit at/above BFE + 1 foot (§ 6-306(E))

Summary

Any new home or substantial improvement in Alexandria's mapped AE or AH flood zones must have its lowest floor, including the basement, elevated to at least one foot above the base flood elevation. Section 6-307(A) sets that one-foot freeboard for residential construction, and a matching standard applies to commercial and mixed-use buildings.

(A)Residential construction.(1)New construction or substantial improvement or any residential building or structure and their extensions and accessory buildings or structures in Zones A, AE, and with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood elevation plus 1-foot.(2)No building permit for the substantial improvement of an existing residential building shall be at least one foot issued unless the building has the lowest floor (including the basement) elevated to or above the base flood elevation plus 1-foot.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 156 | Zoning: Supplement 103).

Full Breakdown

Section 6-307 spells out the elevation math that applies once a parcel's base flood elevation (BFE) has been established from FEMA's Flood Insurance Study or a certified engineering analysis. Residential buildings, including additions and accessory structures, in Zones A, AE, and AH must have their lowest floor, basement included, elevated to or above the BFE plus one foot; no building permit for a substantial improvement of an existing home can issue unless that freeboard is met. Non-residential and mixed-use buildings face the same one-foot freeboard, but Section 6-307(B)(3) lets them dry-floodproof instead of elevating, provided a registered engineer or architect certifies the building is watertight below the BFE-plus-one-foot line and no floor below that line is used for human or animal habitation, food storage, or food preparation.

2-percent annual chance flood elevation. Mechanical, electrical, heating, and plumbing equipment must likewise sit at or above the base flood elevation plus one foot under Section 6-306(E), and any fully enclosed space left below that line can only be used for parking, building access, or storage, built from flood damage-resistant materials, with vents sized to at least one square inch per square foot of enclosed area.

Violations & Fines

Issuing or relying on a building permit without the required base-flood-elevation-plus-one-foot freeboard violates Section 6-307. Alexandria's floodplain administrator can withhold a certificate of occupancy, require an elevation certificate before final approval, and order retrofits, additional fill, or dry-floodproofing before a noncompliant structure may be occupied; the city also maintains elevation certifications on file as a condition of the property's ongoing eligibility in the National Flood Insurance Program.

Frequently Asked Questions

How high above the flood line must I build in Alexandria?
At least one foot above the base flood elevation. Section 6-307(A)(1) requires the lowest floor, including the basement, of new residential construction or a substantial improvement in Zones A, AE, or AH to be elevated to or above the base flood elevation plus one foot.
Can a commercial building in Alexandria's floodplain skip elevating?
Yes, through dry-floodproofing. Section 6-307(B)(3) allows non-residential buildings to be floodproofed instead of elevated, but a registered engineer or architect must certify the structure is watertight up to the base flood elevation plus one foot, and no space below that line can be used for food storage, preparation, or habitation.
Where do mechanical systems like furnaces have to sit?
At or above the base flood elevation plus one foot. Section 6-306(E) requires water heaters, furnaces, electrical panels, and similar equipment to be installed above that line, with separate circuits serving any area below it dropped from above rather than run through the flood-prone space.

Sources & Official References

Other rules in Alexandria

All Alexandria rules

Compare Alexandria to another location·View the Virginia environmental rules overview

Get notified when Flood Elevation Requirements in Alexandria, VA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.