Key Facts

Freeboard
1 ft above base flood elevation (BFE)
Applies to
New construction and substantial improvements
Nonresidential option
Certified flood-proofing instead of elevation
Utility equipment
Must sit at or above the BFE
Verification
City engineer confirms as-built elevation before CO

Summary

Bristol requires new residential construction and substantial improvements inside a special flood hazard area to elevate the lowest floor, including any basement, at least one foot above the base flood elevation, per Appendix D § 5.3.1(a). Utility equipment serving the structure must sit at or above that same elevation, and nonresidential buildings face the identical one-foot standard or certified flood-proofing instead.

5.3.1. (a) Residential construction. New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated at least to one (1) foot above the base flood elevation (BFE). Electrical, plumbing, machinery or other utility equipment that service the structure must be elevated to or above the BFE. ... 5.3.2. (b) Nonresidential construction. (1)New construction or substantial improvement of any commercial, industrial, or nonresidential structure located in Zone A1-30, AE & AH shall have the lowest floor, including basement, elevated at least to one (1) foot above the level of the base flood elevation; or(2)Non-residential structures located in all A-zone may be flood-proofed in lieu of being elevated provided that together with all attendant utilities and sanitary facilities the areas of the structure below the required elevation are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.

Full Breakdown

Section 5.3.1(a) of Appendix D, Flood Damage Prevention, sets Bristol's freeboard standard: in every area of special flood hazard where base flood elevation data exists, new construction or substantial improvement of a residential structure must have its lowest floor, including any basement, elevated at least one foot above the base flood elevation (BFE), and all electrical, plumbing, machinery and other utility equipment serving the structure must likewise sit at or above the BFE. Section 5.3.2(b) applies the same one-foot-above-BFE floor to new or substantially improved commercial, industrial and other nonresidential structures in Zones A1-30, AE and AH, but lets the owner flood-proof instead of elevate if a registered professional engineer or architect certifies the design is watertight and can resist hydrostatic and hydrodynamic loads.

Elevated buildings with enclosed space below the BFE must be built to let floodwaters equalize automatically, either under an engineer's certification or by meeting minimum criteria under § 5.3.3: at least two openings totaling one square inch of net area per square foot of enclosed space, with the bottom of every opening no higher than one foot above grade, and no electrical or plumbing connections below the BFE. Above-ground fuel storage tanks must be elevated above the BFE on a concrete pad or anchored with tie-downs, with the fill pipe extended above the BFE and a screw cap that keeps floodwater out (§ 5.1.12).

Manufactured homes placed for 180 days or more face the same one-foot-above-BFE elevation on a permanent, anchored foundation (§ 5.1.8(a)). The city engineer verifies the as-built lowest-floor elevation before issuing a certificate of occupancy (§ 4.2.4).

Violations & Fines

Failing to elevate a structure to the required one-foot freeboard is enforced the same way as any other violation of Appendix D: § 7.6 makes it a misdemeanor, carrying a fine of up to $250.00 per day if done willfully, up to $100.00 per day otherwise, or up to ten days in jail, or both, plus the city's costs and legal fees, and the city engineer will withhold a certificate of occupancy until the as-built elevation is verified.

Frequently Asked Questions

How high above flood level must a new Bristol home be built?
Section 5.3.1(a) of Appendix D requires the lowest floor, including any basement, to sit at least one foot above the base flood elevation, and any electrical, plumbing or mechanical equipment serving the home must be installed at or above that same elevation.
Can a commercial building be flood-proofed instead of elevated?
Yes. Section 5.3.2(b) lets nonresidential structures in Zones A1-30, AE and AH substitute certified flood-proofing for elevation, provided a registered engineer or architect certifies the design is watertight and can resist hydrostatic and hydrodynamic forces.
What if my house has an enclosed area below the flood elevation?
Section 5.3.3 requires that space to be designed so floodwaters can enter and exit automatically, with at least two vents totaling one square inch per square foot of enclosed area, vent bottoms no higher than a foot above grade, and no electrical or plumbing connections below the BFE.
Does the freeboard rule apply to manufactured homes too?
Yes, under § 5.1.8(a) any manufactured home placed for 180 days or more must be elevated so its lowest floor sits at least one foot above the base flood elevation, on a permanent foundation anchored to resist flotation and lateral movement.

Sources & Official References

Other rules in Bristol

All Bristol rules

Compare Bristol to another location·View the Connecticut environmental rules overview

Get notified when Flood Elevation Requirements in Bristol, CT changes