Joliet, IL Environmental Rules: Flood Elevation Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard added
1 foot above base flood elevation
Fill setback beyond foundation
At least 10 feet
Fill lift depth before compaction
1 foot maximum
Open foundation vent height limit
1 foot above grade
Vent opening area
1 sq in per sq ft enclosed
Insurance premium risk cited for variance
Up to $25 per $100 coverage

Summary

Joliet adds one foot of freeboard on top of the base flood elevation to set the flood protection elevation, and the lowest floor, including the basement, of any new or substantially improved building in the flood plain must sit at or above that line.

Flood protection elevation (FPE) shall mean the elevation of the base flood one hundred (100) year frequency flood plus one (1) foot of freeboard at any given location in the SFHA. ... A residential or non-residential building, when allowed, may be constructed on permanent land fill in accordance with the following: a. The lowest floor, (including basement) shall be at or above the flood protection elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 200).

Full Breakdown

The article defines the flood protection elevation (FPE) in Sec. 8-502 as the base flood, also called the one hundred year frequency flood, plus one foot of freeboard added for a margin of safety against calculation uncertainty, localized conditions and wave or debris effects. Sec. 8-509(5) requires that all buildings within the SFHA be protected from flood damage below the FPE, and applies that duty to new construction, substantial improvements that add more than 20 percent to the first-floor area, buildings with substantial flood damage, new manufactured home placements, and travel trailers sited for more than 180 days.

Sec. 8-509(6) sets out one compliance path: a building placed on permanent fill must have its lowest floor, including the basement, at or above the flood protection elevation, with the fill extending at least ten feet beyond the foundation before sloping below the FPE, placed in lifts no greater than one foot before compaction, and protected against erosion and scour. Sec. 8-509(7) offers an elevation-on-open-foundation alternative: the building can instead sit on crawl space, stilts, piles or walls that stay open to floodwaters, provided the openings are no higher than one foot above grade, number at least two, and total at least one square inch of net opening for every square foot of enclosed area below the FPE.

Violations & Fines

Building below the required flood protection elevation is a violation of Sec. 8-509's permitting requirements, enforced the same way as any Article X violation: ten days' written notice under Sec. 8-513, then possible circuit court injunction and the general Sec. 1-8 code penalty per day of continuing violation. A variance that lessens the required protection triggers a mandatory written warning under Sec. 8-511(2) that flood insurance premiums can rise as much as $25 per $100 of coverage and that the applicant must acknowledge the added risk in writing.

Frequently Asked Questions

How much freeboard does Joliet require above base flood elevation?
One foot. Sec. 8-502 defines the flood protection elevation as the base flood (the one hundred year frequency flood) plus one foot of freeboard, and Sec. 8-509(5) requires protected buildings to meet that elevation, not just the bare base flood elevation.
Can I meet Joliet's flood elevation rule by elevating on piers instead of fill?
Yes. Sec. 8-509(7) allows elevating the building on crawl space, stilts, piles or walls open to floodwaters instead of fill, as long as the flood vents sit no more than one foot above grade and provide at least one square inch of opening per square foot of enclosed area below the flood protection elevation.
Does a basement count toward Joliet's lowest floor elevation rule?
Yes. Sec. 8-509(6)a specifically requires the lowest floor, including the basement, to be at or above the flood protection elevation when a building is placed on permanent fill.

Sources & Official References

Other rules in Joliet

All Joliet rules

Compare Joliet to another location·View the Illinois environmental rules overview

Get notified when Flood Elevation Requirements in Joliet, IL changes