Key Facts

Freeboard required
1 foot above base flood elevation, § 5-72(B)(1)(a)
Applies to
Lowest floor, including basement, new/substantially improved structures
Nonresidential alternative
Floodproofing to 1 ft above BFE, engineer-certified
Enclosed area below floor
2+ vents, 1 sq in. per sq ft, no higher than 1 ft above grade
Manufactured homes
Same 1-ft-above-BFE elevation standard (§ 5-72(C))

Summary

New and substantially improved buildings inside Kirkwood's mapped flood zones must sit above the base flood elevation, not just at it. Section 5-72(B)(1) requires the lowest floor, including any basement, of a residential structure to be elevated a full foot above base flood elevation, with nonresidential buildings allowed to floodproof instead.

1. In all areas identified as numbered and unnumbered A zones and AE zones where base flood elevation data have been provided as set forth in Subsection A.2 of this section, the following provisions are required: a. Residential construction. New construction or substantial improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one foot above base flood elevation. b. Nonresidential construction. New construction or substantial improvement of any commercial, industrial, or other nonresidential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one foot above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

Full Breakdown

Where base flood elevation data exist for a mapped A or AE zone, § 5-72(B)(1)(a) requires new construction or a substantial improvement of a residential structure, including a manufactured home, to have its lowest floor, including any basement, elevated to one foot above the base flood elevation, a one-foot freeboard margin above the minimum FEMA standard. Subsection (b) gives nonresidential buildings, such as commercial or industrial structures, the same one-foot elevation option or a floodproofing alternative: the structure can instead be built watertight below the base flood elevation, with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads, but only if a registered professional engineer or architect certifies the design and files that certification with the Floodplain Administrator under § 5-71(C)(9).

Any fully enclosed area below the lowest floor used only for parking, building access or storage, and that can flood, must include a minimum of two openings totaling at least one square inch of net area for every square foot of enclosed area, with the bottom of every opening no higher than one foot above grade, so floodwater can enter and drain automatically. Manufactured homes get the same one-foot-above-base-flood-elevation standard under § 5-72(C), anchored against flotation, collapse or lateral movement.

Violations & Fines

A residential or nonresidential structure built below the § 5-72(B) elevation standard without an engineer-certified floodproofing alternative violates Article VI and is a misdemeanor under § 5-74, punishable by a fine of up to $500 plus case costs, with each day the deficient structure stands counted as a separate offense.

Frequently Asked Questions

How high above the flood line does my house have to be built in Kirkwood?
One foot above the base flood elevation. Section 5-72(B)(1)(a) requires the lowest floor, including any basement, of a new or substantially improved residential structure in a mapped A or AE zone to be elevated a full foot above that FEMA benchmark, not merely up to it.
Can a commercial building in the floodplain be floodproofed instead of elevated?
Yes. Section 5-72(B)(1)(b) lets a nonresidential structure either elevate one foot above base flood elevation or be floodproofed watertight below that elevation, but only with certification from a registered professional engineer or architect filed with the Floodplain Administrator.
What are the venting rules for a flood-prone garage or crawl space?
Section 5-72(B)(1)(c) requires at least two openings totaling one square inch of net area per square foot of enclosed area that can flood, with every opening's bottom no higher than one foot above grade, so water can automatically flow in and out.

Sources & Official References

Other rules in Kirkwood

All Kirkwood rules

Compare Kirkwood to another location·View the Missouri environmental rules overview

Get notified when Flood Elevation Requirements in Kirkwood, MO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in St. Louis County handle flood elevation requirements.

Florissant, MO
Significant Restrictions