Skip to main content
CityRuleLookup

Kyle, TX Environmental Rules: Flood Elevation Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Elevation standard
Lowest floor at/above base flood elev.
Certification required
PE, architect, or land surveyor
Enclosure openings
1 sq in per sq ft of area
Manufactured home rule
Same elevation, anchored foundation
RV exemption
Under 180 consecutive days on site

Summary

City Code Section 17-83 requires new and substantially improved residential structures in a Kyle special flood hazard area to have their lowest floor elevated to or above the base flood elevation, certified by a registered engineer, architect, or land surveyor.

In all areas of special flood hazard, where base flood elevation data has been provided as set forth in section 17-26, 17-52(8) or 17-84(c), the following provisions are required: (1) Residential construction.New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to or above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 17-53(a)(1) is satisfied. ... be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to or above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement.

Full Breakdown

Under City Code Section 17-83, in any Kyle special flood hazard area where base flood elevation data has been provided, new construction and substantial improvement of a residential structure must have its lowest floor, including any basement, elevated to or above the base flood elevation, and a registered professional engineer, architect, or land surveyor must certify to the floodplain administrator that the standard is satisfied. Nonresidential structures under Section 17-83(2) may instead be floodproofed watertight below the base flood level if a registered engineer or architect certifies the design, with the floodproofing elevation recorded by the floodplain administrator.

Section 17-83(3) requires any enclosure below the lowest floor used only for parking, building access, or storage to include openings that automatically equalize floodwater pressure, at least two openings totaling one square inch of net area per square foot of enclosed area, with the bottom of each opening no higher than one foot above grade. Manufactured homes placed or substantially improved within Zones A1-30, AH, or AE must, under Section 17-83(4), be elevated on a permanent foundation so the lowest floor sits at or above the base flood elevation and be anchored to resist flotation, collapse, and lateral movement, while recreational vehicles under Section 17-83(5) are exempt only if they stay fewer than 180 consecutive days, remain licensed and ready for highway use, or otherwise meet the same permit and elevation standards as manufactured homes. Section 17-82 separately requires all new construction to be anchored against flotation and built with flood-resistant materials and utilities located to prevent water intrusion.

Violations & Fines

Failing to elevate a residential structure's lowest floor to or above the base flood elevation, or building without the required engineer's certification under Section 17-83, is a Chapter 17 violation subject to the Section 17-20 penalty of up to $2,000.00 per day, and the floodplain administrator may deny the Section 17-53 permit or issue a stop-work order until the elevation standard is met.

Frequently Asked Questions

How high must a new house be built in a Kyle flood zone?
City Code Section 17-83(1) requires the lowest floor, including any basement, of a new or substantially improved residential structure in a Kyle special flood hazard area to be elevated to or above the base flood elevation.
Who certifies flood elevation compliance in Kyle?
Section 17-83(1) requires a registered professional engineer, architect, or land surveyor to certify to the floodplain administrator that the lowest floor meets or exceeds the base flood elevation.
Can a commercial building in Kyle be floodproofed instead of elevated?
Yes. Section 17-83(2) lets a nonresidential structure be designed watertight below the base flood level instead of elevated, if a registered engineer or architect certifies the design and the floodproofing elevation is recorded with the floodplain administrator.
Are manufactured homes held to Kyle's base flood elevation rule?
Yes. Section 17-83(4) requires manufactured homes placed or substantially improved in Zones A1-30, AH, or AE to have their lowest floor elevated to or above the base flood elevation on an anchored permanent foundation.

Sources & Official References

Other rules in Kyle

All Kyle rules

Texas rules heatmap·Compare Kyle to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Kyle, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.