Lakeville, MN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- Lakeville City Code § 11-101-7.C
- Freeboard
- 1 foot above regional flood elevation
- Applies to
- FW, FF, GFD floodplain districts
- Lakes without BFE
- Use regional flood elevation table
- Map basis
- Dakota County Flood Insurance Study, NAVD88
- As-built certification
- City engineer under § 11-101-23.G
Summary
In the City of Lakeville, Minnesota, new construction in the floodplain overlay district must be built to the regulatory flood protection elevation, which Lakeville City Code section 11-101-7.C sets at no lower than one foot above the elevation of the regional flood, plus any increase in flood height caused by encroachments on the floodplain from designation of the floodway. That one foot margin is the city's freeboard requirement.
C. Regulatory Flood Protection Elevation: The regulatory flood protection elevation shall be an elevation no lower than one foot (1') above the elevation of the regional flood plus any increases in flood elevation caused by encroachments on the floodplain that result from designation of floodway.
Full Breakdown
Section 11-101-7.C defines the "regulatory flood protection elevation" as an elevation no lower than one foot above the elevation of the regional flood, plus any increases in flood elevation caused by encroachments on the floodplain that result from designation of a floodway; that one foot cushion above the base regional flood is Lakeville's freeboard standard, and it is the elevation to which lowest floors, mechanical equipment, and floodproofing in the FW, FF, and GFD districts must be built or protected under chapter 101. For lakes without a FEMA base flood elevation, section 11-101-7.D substitutes a regional flood elevation drawn from the Flood Insurance Study for Dakota County or the Lakeville water resources management plan, referenced to the NAVD88 datum, and lists specific elevations for Crystal Lake, Goose Lake, Kingsley Lake, Lake Marion, Lee Lake, Orchard Lake, and Raven Lake.
Accessory structures that are floodproofed rather than elevated must still get mechanical and utility equipment above the regulatory flood protection elevation or otherwise properly floodproofed, and must include openings sized at one square inch per square foot of enclosed flood-prone area under section 11-101-11.E. The Regional Flood Elevation table and the FEMA panel numbers were both adopted by reference under section 11-101-7.B, dated December 2, 2011, and the city engineer certifies as-built elevations for elevated or floodproofed structures under subsection 11-101-23.G. The freeboard standard was adopted by Ordinance 883 on September 19, 2011.
Violations & Fines
Building a lowest floor, or leaving mechanical equipment, below the regulatory flood protection elevation set by section 11-101-7.C violates chapter 101, and the city can withhold a certificate of occupancy or require an as-built elevation survey certified by a registered professional engineer before approving the structure. Because the freeboard rule is part of Title 11, noncompliance also carries the citywide misdemeanor penalty under Lakeville City Code section 1-4-1, with each day of continuing violation a separate offense under section 1-4-2.
Frequently Asked Questions
How much freeboard does Lakeville require above the base flood?
What if my lake has no FEMA base flood elevation on file?
Do floodproofed accessory buildings still need to meet an elevation standard?
Who confirms a new building actually meets the elevation requirement?
Sources & Official References
Other rules in Lakeville
Compare Lakeville to another location·View the Minnesota environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.