Key Facts

Residential freeboard
Lowest floor 1 ft above BFE minimum
Nonresidential freeboard
1 ft above BFE or ASCE 24, greater
No BFE available
Lowest floor 2 ft above adjacent grade
Manufactured homes
1 ft above BFE, anchored foundation
Enclosed area vents
1 sq in per sq ft, openings ≤1 ft above grade
Administering office
Floodplain Administrator, Development Services

Summary

Renton requires new and substantially improved buildings in mapped flood hazard areas to raise the lowest floor at least one foot above the base flood elevation, with mechanical equipment held to the same freeboard. Where no BFE data exists, the floor must sit at least two feet above the highest adjacent grade.

In AE and A1-30 zones or other A zoned areas where the base flood elevation has been determined or can be reasonably obtained, new construction and substantial improvement of any residential structure shall have the lowest floor, which for the purposes of this Section includes basement or attached garage as described in subsection G4di(e)(4) of this Section, elevated one foot (1') or more above the base flood elevation. Mechanical equipment, ductwork, and utilities shall be elevated at least one foot (1') above the base flood elevation. ... New construction and substantial improvement of any residential structure in an Unnumbered A zone, for which a base flood elevation is not available and cannot be reasonably obtained, shall be reasonably safe from flooding, but in all cases the lowest floor and any attached garage floor shall be at least two feet (2') above the highest adjacent grade.

View official code

Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 6197, passed August 10, 2026).

Full Breakdown

d, the City's Specific Standards for flood hazard areas set the actual construction floor. In AE and A1-30 zones, or other A-zoned areas where a base flood elevation (BFE) has been determined or can reasonably be obtained, new construction and substantial improvement of a residential structure must have its lowest floor, defined to include a basement or attached garage, elevated one foot or more above the BFE. Mechanical equipment, ductwork, and utilities carry the same one-foot freeboard requirement. Nonresidential construction (commercial, industrial, or other) is held to the same one-foot floor elevation or to the elevation required by ASCE 24, whichever is greater, and its mechanical equipment and utilities follow the same rule.

Manufactured homes placed or substantially improved in Zones A1-A30, AH, and AE must sit on a permanent foundation with the lowest floor at least one foot above BFE and be anchored against flotation, collapse, and lateral movement. Where a BFE cannot reasonably be obtained (an Unnumbered A zone), the lowest floor, including any attached garage floor, must instead sit at least two feet above the highest adjacent grade; the code specifically warns that failing to reach that two-foot mark can raise flood insurance premiums. Any fully enclosed area built below the lowest floor may be used only for parking, building access, or storage, and must include flood vents: a minimum of two openings totaling at least one square inch of net area per square foot of enclosed space, with opening bottoms no higher than one foot above grade, unless a registered engineer or architect certifies an alternative design. ii.

Violations & Fines

The City will not issue or finalize a development permit in a mapped flood hazard area without the required pre-construction and as-built elevation certificates on file with Development Services, and the Floodplain Administrator's review under RMC 4-3-050.D.3.b confirms compliance before any approval is granted. Building below the one-foot (or two-foot, in Unnumbered A zones) freeboard threshold, or enclosing space below the lowest floor without the required flood-vent openings, blocks occupancy sign-off and can trigger higher federal flood insurance rates under the code's own warning language.

Frequently Asked Questions

How high above base flood elevation must a new Renton home be built?
In AE and A1-30 zones where a base flood elevation has been set, RMC 4-3-050.G.4.d.i requires the lowest floor of new or substantially improved residential structures, including any basement or attached garage, to sit at least one foot above that elevation, with mechanical equipment held to the same one-foot minimum.
What happens if there's no base flood elevation data for my Renton lot?
In an Unnumbered A zone where BFE data cannot reasonably be obtained, RMC 4-3-050.G.4.d.i(c) requires the lowest floor and any attached garage floor to be at least two feet above the highest adjacent grade instead, and the code notes that falling short can mean higher flood insurance rates.
Can I finish a basement below the required flood elevation in Renton?
Only for parking, building access, or storage. RMC 4-3-050.G.4.d.i(d)-(e) requires any fully enclosed area below the lowest floor to either stay unfinished for those uses or include engineered flood vents sized at one square inch per square foot of enclosed area, with openings no higher than one foot above grade.

Sources & Official References

Other rules in Renton

All Renton rules

Compare Renton to another location·View the Washington environmental rules overview

Get notified when Flood Elevation Requirements in Renton, WA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in King County handle flood elevation requirements.

Seattle, WA
Some Restrictions
Kirkland, WA
Some Restrictions
Kent, WA
Some Restrictions
Auburn, WA
Some Restrictions
Bellevue, WA
Some Restrictions
Federal Way, WA
Some Restrictions