Federal Way, WA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard standard
- 1 foot above BFE, residential AE zones
- Critical facilities
- 3 feet above BFE or 500-year flood level
- Opening requirement
- 1 sq in per sq ft of enclosed area
- Opening height
- No higher than 1 foot above grade
- Certification
- FEMA Form 81-31, Section B by city
- Enforcing office
- Federal Way Community Development Director
- Variance insurance risk
- Up to $25 per $100 of coverage
Summary
Federal Way requires new and substantially improved residential structures in AE flood zones to elevate the lowest floor, including any basement, at least one foot above the base flood elevation. A floodplain development permit and an elevation certificate from a licensed engineer or surveyor are mandatory before and after construction.
(1) Residential construction in zone AE.
(a) New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated one foot or more above the base flood elevation (BFE).
(b) Fully enclosed areas below the lowest floor that are subject to flooding are prohibited, or if used solely for parking, access or storage, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters... (i) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. (ii) The bottom of all openings shall be no higher than one foot above grade.
Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 26-1049, passed August 11, 2026).
Full Breakdown
140(1)(a) sets the city's freeboard standard: new construction and substantial improvement of any residential structure in zone AE must have the lowest floor, including the basement, elevated one foot or more above the base flood elevation (BFE). Enclosed areas below that elevated floor are banned outright unless used solely for parking, building access, or storage, and even then they must be engineered to automatically equalize hydrostatic pressure. 140(1)(b) requires a minimum of two openings with at least one square inch of net area per square foot of enclosed space, with the bottom of every opening no higher than one foot above grade, or certification from a registered professional engineer or architect that an equivalent design meets the standard.
The code specifically warns that standard IBC/IRC foundation vents built outside the floodplain do not satisfy this rule and are often permitted in error, and that a partially ventilated crawlspace can trigger a 20 to 25 percent surcharge on the annual flood insurance premium. 140(3), or may instead be floodproofed watertight to that elevation with structural components certified to resist hydrostatic and hydrodynamic loads. 140(5). 040 to include schools, hospitals, and emergency response installations, face a stricter three-foot-above-BFE standard when sited in the special flood hazard area. 080. Upon completion, a registered professional engineer or surveyor must certify to the director that the lowest-floor elevation requirement was actually met.
Violations & Fines
The director of the Federal Way community development department serves as the city's floodplain administrator and enforces this chapter under FWRC 19.142.080 and 19.142.130 by reviewing building permit applications for compliance with the elevation and certification requirements. A structure built with its lowest floor below the base flood elevation without an approved variance faces sharply higher flood insurance costs. FWRC 19.142.100(7) requires the director to give written notice that a granted variance allowing construction below BFE will raise flood insurance premiums up to $25.00 for every $100.00 of coverage and increases risk to life and property. Failure to submit the required post-construction elevation certification blocks final occupancy approval.
Frequently Asked Questions
How high above base flood elevation must a Federal Way house be built?
Can I have an enclosed space below the elevated floor?
Do standard foundation vents meet Federal Way's flood venting rule?
What elevation applies to critical facilities like schools or fire stations?
Sources & Official References
Other rules in Federal Way
Compare Federal Way to another location·View the Washington environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in King County handle flood elevation requirements.