Key Facts

Freeboard
Base flood elevation plus 1 foot
Residential floor
Lowest floor at or above FPE
No-data fallback
2 feet above highest adjacent grade
Commercial option
Dry floodproof to FPE instead of elevating
Accessory exemption
Structures 600 sq ft or less
Penalty
4th-degree misdemeanor, Sec. 971.99

Summary

Springfield, Ohio's floodplain code sets a Flood Protection Elevation equal to the base flood elevation plus one foot of freeboard, and new or substantially improved residential structures in mapped flood hazard areas must have their lowest floor, including any basement, built to or above that elevation under Codified Ordinances Section 971.04(d)(4).

(p) “Flood Protection Elevation” (FPE) means the base flood elevation plus one [1] foot of freeboard. In areas where no base flood elevations exist from any authoritative source, the flood protection elevation can be historical flood elevations, or base flood elevations determined and/or approved by the floodplain administrator. ... (4) New construction and substantial improvement of any residential structure, including manufactured homes, shall have the lowest floor, including basement, elevated to or above the flood protection elevation. Where flood protection elevation data are not available, the structure shall have the lowest floor, including basement, elevated at least two feet above the highest adjacent natural grade.

Full Breakdown

Springfield's Floodplain Regulations define Flood Protection Elevation (FPE) as the base flood elevation plus one foot of freeboard; where no base flood elevation exists from an authoritative source, the Floodplain Administrator may substitute historical flood elevations or an approved determination (Section 971.02(p)). New construction and substantial improvement of any residential structure, including manufactured homes, must have the lowest floor, including any basement, elevated to or above the FPE; if FPE data are not available, the lowest floor must sit at least two feet above the highest adjacent natural grade (Section 971.04(d)(4)).

Commercial, industrial and other nonresidential structures face the same lowest-floor standard unless they are dry floodproofed to the FPE, built with components rated to resist hydrostatic and hydrodynamic loads, and certified on a FEMA Floodproofing Certificate by a registered engineer or architect (Section 971.04(e)(2)). Structures elevated on pilings, columns, posts or solid perimeter walls without a basement may enclose the area below the lowest floor only for parking, building access or storage, and the enclosure needs either an engineer-certified automatic equalization design or at least two openings on different walls totaling one square inch of net area per square foot of enclosed space, with opening bottoms no higher than one foot above grade (Section 971.04(d)(5)).

Accessory structures of 600 square feet or less can get relief from full elevation or floodproofing if built of flood-resistant materials, anchored against flotation and fitted with the same low-opening venting (Section 971.04(f)). Repair of a historic structure is exempt from these elevation standards when the work is the minimum necessary to keep its historic designation (Section 971.04(d)(7)).

Violations & Fines

Building below the required Flood Protection Elevation without a floodplain development permit is enforced the same as any other Chapter 971 violation: a strict liability offense and fourth-degree misdemeanor under Section 971.99, with fines or imprisonment as provided by law and each day of noncompliance treated as a separate offense. Before prosecution, the Floodplain Administrator must issue a written notice specifying which elevation requirement was violated and a deadline to elevate, floodproof or otherwise correct the structure (Section 971.06(b)).

Frequently Asked Questions

How is Flood Protection Elevation calculated in Springfield, Ohio?
It equals the base flood elevation plus one foot of freeboard under Section 971.02(p). If no base flood elevation is available from an authoritative source, the Floodplain Administrator can approve historical flood elevations in its place.
Do commercial buildings have to be elevated to the same height as houses?
Not necessarily. Section 971.04(e)(2) lets nonresidential structures skip elevation if they are dry floodproofed watertight to the Flood Protection Elevation, built with hydrostatic-load-resistant components, and certified by a registered engineer or architect on a FEMA Floodproofing Certificate.
What if there's no base flood elevation data for my Springfield lot?
Section 971.04(d)(4) sets a fallback for that case: the lowest floor, including any basement, must be built at least two feet above the highest adjacent natural grade instead of at the Flood Protection Elevation, and the Floodplain Administrator may substitute historical flood data under Section 971.02(p) if any exists.

Sources & Official References

Other rules in Springfield

All Springfield rules

Compare Springfield to another location·View the Ohio environmental rules overview

Get notified when Flood Elevation Requirements in Springfield, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.