Cicero, IL Fire Regulations: Smoke Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Minimum detectors
1 per living level and per unit
Placement
Within 15 ft of sleeping rooms
Ceiling clearance
6 in from wall (or 6-12 in below ceiling)
Standard
UL 217 (1976) or Electrical Code
Fine
$250.00-$750.00 (Sec. 42-31(h))

Summary

Cicero requires at least one approved, working smoke detector in every residential unit and living level, plus one at the top of every interior stairwell in multi-unit and mixed-occupancy buildings. Town Code Sec. 42-31 sets exact placement distances and bans disabling a detector, with fines of $250.00 to $750.00.

(b) Location. Not less than one approved smoke detector shall be installed in each single-family residential unit and multiple-dwelling unit as defined in the comprehensive zoning ordinance in appendix A to this Code. A detector shall be installed on the ceiling and at least six inches from any wall or on a wall located not less than six inches or more than 12 inches from the ceiling and within 15 feet of all rooms used for sleeping purposes, with not less than one detector per living level. (c) Stairwell installation. All multiple dwellings and buildings of mixed occupancy having any residential units shall contain not less than one approved smoke detector at the uppermost ceiling of all interior stairwells. ... (f) Removal of batteries unlawful. It shall be unlawful for any person to remove batteries or in any way render inoperable any smoke detector required to be installed by this section... (h) Violation. There shall be a minimum fine of $250.00 and a maximum of $750.00 for violations of this section.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 121).

Full Breakdown

Sec. 42-31 requires every building of residential or mixed occupancy with any residential units to carry approved, operable smoke detectors. At least one detector must go in each single-family or multiple-dwelling unit, installed on the ceiling at least six inches from any wall, or on a wall positioned between six and twelve inches below the ceiling, and located within 15 feet of every room used for sleeping, with a minimum of one detector per living level. Multiple dwellings and mixed-occupancy buildings must additionally place at least one approved smoke detector at the uppermost ceiling of every interior stairwell, installed to the same wall or ceiling clearance rules.

All required detectors must be ionization chamber or photoelectric type meeting Underwriters' Laboratories Standard UL 217 (1976) and any applicable Electrical Code provisions. A building equipped throughout with an approved automatic sprinkler system is exempt from the whole section. Removing batteries or otherwise disabling a required smoke detector is unlawful, except for a building owner, manager or agent conducting scheduled battery replacement or repair. A violation of any part of Sec. 00 under subsection (h).

Violations & Fines

A missing, misplaced or disabled smoke detector violates Sec. 42-31 and draws a fine of not less than $250.00 nor more than $750.00 per offense under subsection (h). Removing batteries from a required detector is separately unlawful unless done by a building owner, manager or agent for scheduled replacement or repair, and a fully sprinklered building is exempt from the detector mandate altogether.

Frequently Asked Questions

How many smoke detectors does Cicero require in an apartment?
At least one approved smoke detector per living level and per unit under Sec. 42-31(b), placed within 15 feet of every room used for sleeping. Buildings with interior stairwells need an additional detector at the top of each stairwell under subsection (c).
Can I remove the batteries from my smoke detector?
No, not as a resident. Sec. 42-31(f) makes it unlawful to remove batteries or otherwise disable a required smoke detector, though a building owner, manager or agent may do so briefly for scheduled battery replacement or repair.
Are sprinklered buildings exempt from the smoke detector rule?
Yes. Sec. 42-31(e) exempts any building equipped throughout with an approved automatic sprinkler system from the smoke detector requirements in the rest of the section.

Sources & Official References

Other rules in Cicero

All Cicero rules

Compare Cicero to another location·View the Illinois fire regulations overview

Get notified when Smoke Detectors in Cicero, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Smoke Detectors in Nearby Cities

How other cities in Cook County handle smoke detectors.

Chicago, IL
Some Restrictions
Oak Lawn, IL
Some Restrictions
Tinley Park, IL
Some Restrictions
Oak Park, IL
Some Restrictions
Skokie, IL
Some Restrictions
Schaumburg, IL
Some Restrictions
Evanston, IL
Some Restrictions