Grand Forks, ND Fire Regulations: Smoke Detectors (2026)
Key Facts
- Standard required
- UBC Standard 43-6
- Testing by tenant
- At least monthly
- Testing by owner/manager
- At least annually
- Applies to units existing since
- September 9, 1979
- Tampering fine
- $300 to $500 per offense
- Informant reward
- $100
Summary
Every rental dwelling unit in Grand Forks must have a smoke or products-of-combustion detector meeting UBC Standard 43-6, centrally placed in each hallway leading to sleeping rooms under City Code Section 12-0701. Tenants must test the detector monthly and owners must test it annually, and tampering with one carries a fine of at least three hundred dollars.
Every dwelling unit held for rental purposes shall be provided with a smoke or products-of-combustion detector conforming to UBC Standard 43-6. The detector shall be mounted on the ceiling not less than six (6) inches from the wall, or on the wall between six (6) and twelve (12) inches of the ceiling at a point centrally located in each corridor or area giving access to rooms used for sleeping purposes. Where sleeping rooms are on an upper level, the detector shall be placed directly above the stairway giving access to these rooms.
Full Breakdown
Section 12-0701 requires every dwelling unit held for rental purposes to have a smoke or products-of-combustion detector conforming to UBC Standard 43-6, mounted on the ceiling no less than six inches from the wall, or on the wall between six and twelve inches of the ceiling, centrally located in each corridor or area giving access to sleeping rooms; where sleeping rooms sit on an upper level, the detector must be placed directly above the stairway leading to them. Section 12-0702 requires hardwired detectors to connect to an unswitched circuit, with a holding device for plug-in units, and battery-powered detectors to use only the manufacturer's recommended battery size and type.
Section 12-0703 splits testing duties: the tenant must test the detector according to the manufacturer's instructions at least monthly, while the owner or manager must test it at least annually, keep records of testing and maintenance dates and the names of who performed them, and give tenants written notice of these testing requirements. The article applies to every rental dwelling unit existing on or after September 9, 1979, except new construction or remodeling governed by the building code then in effect, per Section 12-0704. Section 12-0705 bars tampering with, damaging, moving or otherwise disturbing a required detector, though routine maintenance by the owner, hotel or motel proprietor, or their representatives is exempt.
Violations & Fines
Tampering with, damaging or disturbing a required smoke detector under Section 12-0705 carries a fine of not less than three hundred dollars nor more than five hundred dollars per offense. Any other violation of the article is fined up to five hundred dollars, with each day a violation continues a separate offense, and Section 12-0706 pays a one hundred dollar reward for information leading to a conviction.
Frequently Asked Questions
Where must a smoke detector be placed in a rental unit?
Who is responsible for testing the smoke detector, the landlord or the tenant?
Does this rule apply to my older rental building?
What is the penalty for disabling a smoke detector?