Skip to main content
CityRuleLookup

Moore, OK Outdoor Cooking: BBQ & Propane Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing provision
Fire Code § 308.1.4 (Moore Code § 13-101)
Balcony/deck rule
Prohibited within 10 feet of combustible construction
Per-container LP-gas limit
20 pounds water capacity
Aggregate limit (unsprinklered)
100 pounds / 5 containers
Aggregate limit (sprinklered)
40 pounds / 2 containers
Enforcement
Moore Fire Department, § 1-108 penalty

Summary

Moore's local fire code amendment at Section 308.1.4 bars open-flame cooking devices and charcoal grills from combustible balconies and decks, or within 10 feet of combustible construction. Its exceptions cap LP-gas grill containers at 20 pounds each, with a 100-pound aggregate normally, dropping to a 40-pound aggregate where the building has automatic sprinklers.

Section 308.1.4, delete and amend to read: [308.1.4 Open-flame Cooking Devices. Open-flame cooking devices, charcoal grills and other similar devices used for cooking shall not be located or used on combustible balconies, decks, or within 10 feet (3048 mm) of combustible construction.] ... Section 308.1.4, Exception number 1, add text at the end to read: [except that LP-gas containers are limited to a water capacity not greater than 20 pounds (9.08 kg) LP-gas capacity] with an aggregate LP-gas capacity not to exceed l 00 pounds (5 containers).] ... Section 308.1 .4, Exception number 2, delete and amend to read: [2. Where buildings, balconies and decks are protected by an approved automatic sprinkler system, except that LP-gas containers are limited to a water capacity not greater than 20 pounds (9.08 kg) LP-gas capacity, with an aggregate LP-gas capacity not to exceed 40 lbs. (2 containers).

Full Breakdown

Moore adopted the 2018 International Fire Code at Code § 13-101 and locally amended Section 308.1.4, Open-Flame Cooking Devices, to read that open-flame cooking devices, charcoal grills, and other similar cooking devices cannot be located or used on combustible balconies or decks, or within 10 feet (3048 mm) of combustible construction. The city then added its own exception structure for propane appliances: Exception 1 allows LP-gas containers despite the balcony and 10-foot rule, but each container is limited to a water capacity no greater than 20 pounds (roughly a standard 5-gallon barbecue tank), with an aggregate LP-gas capacity across all containers at a location capped at 100 pounds, or five containers.

Exception 2 applies the same 20-pound single-container limit but sets a tighter 40-pound aggregate, or two containers, where the building's balconies and decks are protected by an approved automatic sprinkler system, since sprinklered buildings still receive some tank allowance but not the full unsprinklered amount. This rule is aimed squarely at apartment and multifamily balconies, where propane grills stored or used against a combustible wall or railing pose a fire-spread risk to neighboring units. Violating the fire code amendment is enforced the same way as the rest of the adopted International Fire Code: under Section 110.4 as locally amended, violators are punished under Moore Code § 1-108, and each day a violation continues after notice is a separate offense.

Violations & Fines

Locating or using an open-flame or LP-gas grill on a combustible balcony or deck, or within 10 feet of combustible construction, without qualifying for the tank-size exceptions violates Section 308.1.4. Exceeding the 20-pound single-container limit, or the 100-pound aggregate (40 pounds where sprinklered) is also a violation. Under the fire code's locally amended penalty section, violations are punished per Moore Code § 1-108, and each day a violation continues after notice is a separate offense.

Frequently Asked Questions

Can I use a propane grill on my apartment balcony in Moore?
Only within limits. Moore's local fire code amendment to Section 308.1.4 normally bars open-flame cooking devices from combustible balconies and decks, but an exception allows LP-gas grills there if each container holds no more than 20 pounds of LP-gas and the aggregate at that location does not exceed 100 pounds, or five containers.
Does having a sprinkler system change the propane grill limits in Moore?
Yes. Where the building's balconies and decks are protected by an approved automatic sprinkler system, Exception 2 to Section 308.1.4 still limits each LP-gas container to 20 pounds, but drops the total aggregate allowed at that location to 40 pounds, or two containers, tighter than the 100-pound unsprinklered allowance.
How far from a building must a charcoal or gas grill be used in Moore?
Section 308.1.4 requires open-flame cooking devices, including charcoal grills, to be located and used at least 10 feet (3048 mm) from combustible construction, in addition to the separate ban on using them on combustible balconies or decks, unless a specific LP-gas exception applies.

Sources & Official References

Other rules in Moore

All Moore rules

Compare Moore to another location·View the Oklahoma outdoor cooking overview

Get notified when BBQ & Propane Rules in Moore, OK changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.