Elgin, IL Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Standard luminaire threshold
- More than 1,800 lumens total
- Spot or flood threshold
- More than 900 lumens total
- Light above horizontal plane
- None permitted from covered fixtures
- Height cap near residences or streets
- 25 feet within 50 feet of the line
- Residential lamp exemption
- 100 watts or less per outdoor lamp
- Light trespass limit
- One-half horizontal footcandle
- Plan review office
- Code administration and development services
Summary
Elgin requires any outdoor luminaire rated above 1,800 lumens, and any spot or flood luminaire rated above 900 lumens, to emit no direct light above a horizontal plane through its lowest light-emitting part. Those same fixtures must be mounted 25 feet high or lower when they sit within 50 feet of a residential property line or public street right-of-way line.
Any luminaire [SR] with a lamp [SR] or lamps rated at a total of more than one thousand eight hundred (1,800) lumens [SR], and all spot or flood luminaires [SR] with a lamp [SR] or lamps rated at a total of more than nine hundred (900) lumens [SR], shall not emit any direct light above a horizontal plane through the lowest direct light [SR] emitting part of the luminaire [SR]. Any luminaire [SR] with a lamp [SR] or lamps rated at a total of more than one thousand eight hundred (1,800) lumens [SR], and all flood or spot luminaires [SR] with a lamp [SR] or lamps rated at more than nine hundred (900) lumens [SR], shall be mounted at a height equal to or less than twenty-five (25) feet, when the luminaire is located within fifty (50) feet of a residential property line or a public street right-of-way line.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 7).
Full Breakdown
Section 19.13.125 of the Elgin Municipal Code is the city's glare-control rule, and it works in two parts. The first is a shielding test: a luminaire may not emit any direct light above a horizontal plane drawn through its lowest light-emitting part. In practice that means a fully cut-off fixture aimed down, not a bare bulb or an upward-tilted lamp. The second is a height cap: 25 feet maximum mounting height for the same fixtures when they stand within 50 feet of a residential property line or a public street right-of-way line.
Two lumen thresholds decide which fixtures are caught. An ordinary luminaire is covered when its lamp or lamps are rated at a total of more than 1,800 lumens. A spot or flood luminaire is covered at the lower figure of more than 900 lumens. Fixtures at or below those ratings fall outside this section.
The rule sits inside a larger chapter. Section 19.13.130 sets district standards that apply except as regulated by 19.13.125: a maximum average of 3 footcandles in the residential chapters 19.20 and 19.25, 4 in community facility chapter 19.30, and 5 in business chapter 19.35 and industrial chapter 19.40. Every district carries a 0.6 footcandle minimum on pavement and a 4:1 uniformity ratio, with luminaire height limits of 25, 30, 40 and 40 feet. Light spilling from community facility, business or industrial land onto residential zoned property or a public street right-of-way cannot exceed one-half horizontal footcandle. Single-family detached dwellings, and multiple-family dwellings with residential parking areas, are exempt from the chapter's standards when each outdoor lamp is rated at 100 watts or less.
Section 19.13.115 exempts public street lighting, temporary seasonal decorative lighting, specialized safety lighting such as airport or heliport lighting, and outdoor recreational uses such as ball diamonds, playing fields and tennis courts. Readings are taken with a direct reading, portable light meter, with horizontal footcandle measurements at 3½ feet above the ground (§ 19.13.135).
Violations & Fines
Chapter 19.13 prints no penalty of its own. The department of code administration and development services checks compliance at the lighting plan stage, before any fixture goes in. A luminaire over 1,800 lumens that throws direct light above its horizontal plane, or one mounted above 25 feet within 50 feet of a residential property line or street right-of-way line, fails § 19.13.125. Fixtures installed before the chapter took effect and out of conformance are nonconforming under chapter 19.52.
Frequently Asked Questions
Does a floodlight on my garage have to be shielded?
Do I need a lighting plan to replace or add a fixture?
Can I get approval for a pole taller than 25 feet?
Do ball fields and tennis courts follow the same limits?
What happens to older lights that do not meet the rule?
Sources & Official References
Other rules in Elgin
Compare Elgin to another location·View the Illinois outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.