Elgin, IL Outdoor Lighting: Light Trespass & Shielding (2026)
Key Facts
- Spillover cap
- One-half horizontal footcandle
- Source lots
- Community facility, business, or industrial zoned
- Protected ground
- Residential zoned property and public street rights-of-way
- Measurement
- Portable light meter, 3½ feet above the ground
- Dwelling exemption
- Lamps of 100 watts or less at qualifying homes
- Plan review
- Department of code administration and development services
- Appeals
- Chapter 19.75
Summary
Elgin caps light spilling from community facility, business, and industrial lots onto residential zoned property or a public street right-of-way at one-half horizontal footcandle. Section 19.13.130(D) sets the limit, and section 19.13.135 requires readings from a portable light meter held three and one-half feet above the ground.
The maximum light trespass [SR] permitted to spill over onto any residential zoned property or public street right-of-way from any community facility, business, or industrial zoned property shall not exceed one-half (½) horizontal footcandles. ... Light levels of both direct light [SR] and indirect light [SR] shall be measured in footcandles [SR] with a direct reading, portable light meter. Readings shall be taken only after the cell has been exposed long enough to provide a constant reading. Horizontal footcandle measurements shall be taken at a height of three and one-half (3½) feet above the ground.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 7).
Full Breakdown
The spillover limit sits in Elgin's Outdoor Lighting chapter, Chapter 19.13 of the zoning title, in the Standards section. Subsection D says the maximum light trespass permitted to spill over onto any residential zoned property or public street right-of-way from a community facility, business, or industrial zoned property cannot exceed one-half horizontal footcandle. The rule runs in one direction: the source lot must be zoned community facility, business, or industrial, and the receiving ground is a residential zoned lot or a street right-of-way. The chapter's purpose clause, section 19.13.100, names control of glare and light trespass alongside nighttime safety, security, and energy conservation.
Compliance is measured, not judged by eye. Section 19.13.135 requires both direct and indirect light to be read in footcandles with a direct reading, portable light meter. The reader waits until the cell has been exposed long enough to give a constant reading, and horizontal measurements are taken three and one-half feet above the ground.
The limit is paired with a plan requirement. Under section 19.13.120, an outdoor lighting plan goes to the department of code administration and development services before any outdoor lighting is installed or modified. The plan shows fixture locations, footcandle levels at points across the site, catalog cuts, and a summary table that includes the maximum footcandles at a residential property line or public street right-of-way line. Routine maintenance on existing fixtures needs no plan.
Other rules in the chapter shrink the spill at its source. Section 19.13.125 bars direct light above a horizontal plane from any luminaire rated above 1,800 lumens and from spot or flood luminaires rated above 900 lumens, and caps their mounting height at 25 feet when they sit within 50 feet of a residential property line or street right-of-way line.
Several exemptions apply. Section 19.13.115 excludes public street lighting, temporary seasonal decorative lighting, safety lighting such as airport and emergency operations lighting, and outdoor recreational uses, which must still be aimed to minimize spillover onto residential properties and use a landscaped buffer yard where spillover is unavoidable. Section 19.13.130(B) exempts lighting at single-family detached dwellings and multiple-family dwellings with residential parking areas when the lamps are rated at 100 watts or less.
Violations & Fines
Chapter 19.13 prints no fine schedule of its own for a reading above one-half footcandle. The limit works as a standard: new or modified lighting must show compliance in the plan filed under section 19.13.120, and a meter reading under section 19.13.135 tests an installed fixture. Lighting that predates the chapter and fails the standard is nonconforming under section 19.13.145 and is governed by chapter 19.52.
Frequently Asked Questions
How much light can a Elgin business spill onto a neighboring home?
How does Elgin measure light trespass?
Do homeowners in Elgin have to meet the one-half footcandle limit?
Can a property owner get a variation from the lighting standards in Elgin?
Sources & Official References
Other rules in Elgin
Compare Elgin to another location·View the Illinois outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Light Trespass & Shielding in Nearby Cities
How other cities in this county handle light trespass & shielding.