Skip to main content

Elgin, IL Outdoor Lighting: Light Trespass & Shielding (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Spillover cap
One-half horizontal footcandle
Source lots
Community facility, business, or industrial zoned
Protected ground
Residential zoned property and public street rights-of-way
Measurement
Portable light meter, 3½ feet above the ground
Dwelling exemption
Lamps of 100 watts or less at qualifying homes
Plan review
Department of code administration and development services
Appeals
Chapter 19.75

Summary

Elgin caps light spilling from community facility, business, and industrial lots onto residential zoned property or a public street right-of-way at one-half horizontal footcandle. Section 19.13.130(D) sets the limit, and section 19.13.135 requires readings from a portable light meter held three and one-half feet above the ground.

The maximum light trespass [SR] permitted to spill over onto any residential zoned property or public street right-of-way from any community facility, business, or industrial zoned property shall not exceed one-half (½) horizontal footcandles. ... Light levels of both direct light [SR] and indirect light [SR] shall be measured in footcandles [SR] with a direct reading, portable light meter. Readings shall be taken only after the cell has been exposed long enough to provide a constant reading. Horizontal footcandle measurements shall be taken at a height of three and one-half (3½) feet above the ground.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 7).

Full Breakdown

The spillover limit sits in Elgin's Outdoor Lighting chapter, Chapter 19.13 of the zoning title, in the Standards section. Subsection D says the maximum light trespass permitted to spill over onto any residential zoned property or public street right-of-way from a community facility, business, or industrial zoned property cannot exceed one-half horizontal footcandle. The rule runs in one direction: the source lot must be zoned community facility, business, or industrial, and the receiving ground is a residential zoned lot or a street right-of-way. The chapter's purpose clause, section 19.13.100, names control of glare and light trespass alongside nighttime safety, security, and energy conservation.

Compliance is measured, not judged by eye. Section 19.13.135 requires both direct and indirect light to be read in footcandles with a direct reading, portable light meter. The reader waits until the cell has been exposed long enough to give a constant reading, and horizontal measurements are taken three and one-half feet above the ground.

The limit is paired with a plan requirement. Under section 19.13.120, an outdoor lighting plan goes to the department of code administration and development services before any outdoor lighting is installed or modified. The plan shows fixture locations, footcandle levels at points across the site, catalog cuts, and a summary table that includes the maximum footcandles at a residential property line or public street right-of-way line. Routine maintenance on existing fixtures needs no plan.

Other rules in the chapter shrink the spill at its source. Section 19.13.125 bars direct light above a horizontal plane from any luminaire rated above 1,800 lumens and from spot or flood luminaires rated above 900 lumens, and caps their mounting height at 25 feet when they sit within 50 feet of a residential property line or street right-of-way line.

Several exemptions apply. Section 19.13.115 excludes public street lighting, temporary seasonal decorative lighting, safety lighting such as airport and emergency operations lighting, and outdoor recreational uses, which must still be aimed to minimize spillover onto residential properties and use a landscaped buffer yard where spillover is unavoidable. Section 19.13.130(B) exempts lighting at single-family detached dwellings and multiple-family dwellings with residential parking areas when the lamps are rated at 100 watts or less.

Violations & Fines

Chapter 19.13 prints no fine schedule of its own for a reading above one-half footcandle. The limit works as a standard: new or modified lighting must show compliance in the plan filed under section 19.13.120, and a meter reading under section 19.13.135 tests an installed fixture. Lighting that predates the chapter and fails the standard is nonconforming under section 19.13.145 and is governed by chapter 19.52.

Frequently Asked Questions

How much light can a Elgin business spill onto a neighboring home?
Section 19.13.130(D) limits spillover from a community facility, business, or industrial zoned property onto residential zoned property or a public street right-of-way to one-half horizontal footcandle. Anything above that reading at the receiving property is over the cap. The limit is horizontal, so the meter reading is taken on a level plane, not aimed at the fixture.
How does Elgin measure light trespass?
Section 19.13.135 calls for a direct reading, portable light meter that reads in footcandles. Both direct and indirect light count. The cell must be exposed long enough to give a constant reading, and horizontal footcandle measurements are taken three and one-half feet above the ground.
Do homeowners in Elgin have to meet the one-half footcandle limit?
The limit in section 19.13.130(D) is written for spillover from community facility, business, and industrial zoned lots. Section 19.13.130(B) also exempts outdoor lighting at single-family detached dwellings, and at multiple-family dwellings with residential parking areas, from the chapter's standards when the lamps are rated at 100 watts or less.
Can a property owner get a variation from the lighting standards in Elgin?
Section 19.13.150 allows variations only through chapter 19.70 and only in two instances: an increase in the maximum illumination of a site, or an increase in the maximum mounting height of a luminaire. Neither instance mentions the spillover limit. Requirements, determinations, and interpretations can be appealed under chapter 19.75, per section 19.13.155.

Sources & Official References

Other rules in Elgin

All Elgin rules

Compare Elgin to another location·View the Illinois outdoor lighting overview

Get notified when Light Trespass & Shielding in Elgin, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Light Trespass & Shielding in Nearby Cities

How other cities in this county handle light trespass & shielding.

Aurora, IL
Some Restrictions