Mount Prospect, IL Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Cutoff standard
- Full cutoff, total cutoff angle not more than ninety degrees
- Lenses
- Flat lenses required on all fixtures
- Wall lights
- Full cutoff and fully shielded
- Parking lot pole limit
- District height limit or thirty feet, whichever is less
- Upward facade lighting cap
- 900 lumens, fully shielded
- Exempt from fixture rules
- Single-family properties and architectural facade lighting
Summary
The Village of Mount Prospect requires full cutoff fixtures with a total cutoff angle of not more than ninety degrees, flat lenses, and fully shielded wall lights on most outdoor lighting. Single-family properties and architectural facade lighting are carved out of the fixture rules, and the Director of Community Development can approve alternatives.
2. Fixture Design: Outdoor lighting fixtures shall comply with the following limitations, with the exception of single-family residential properties and architectural facade lighting: a. Full Cutoff Luminaries: Full cutoff luminaries with a total cutoff angle of not more than ninety degrees (90°) shall be used. The Director of Community Development may approve cutoff angles greater than ninety degrees (90°) or the use of fixtures without full cutoff luminaries upon submission of information conclusively demonstrating that the proposed lighting will not cause glare on adjacent properties. b. Under Mounted Lighting: All lighting mounted under a canopy, including, but not limited to, luminaries mounted on or recessed into the lower surface of a canopy, shall be full cutoff. c. Flat Lenses: Flat lenses are required for all lighting fixtures. d. Wall Lights: Wall lights, where used, shall be full cutoff and fully shielded.
Full Breakdown
Fixture design is governed by Section 14.314 of the Village of Mount Prospect zoning chapter. Every outdoor fixture other than a streetlight is covered, but the fixture list applies to everything except single-family residential properties and architectural facade lighting.
Full cutoff luminaires with a total cutoff angle of not more than ninety degrees must be used. The Director of Community Development can approve a wider cutoff angle, or fixtures that are not full cutoff, only when the applicant submits information conclusively demonstrating that the lighting will not cause glare on adjacent properties. Lighting mounted under a canopy, including luminaires on or recessed into the lower surface, must be full cutoff. Flat lenses are required on every fixture, and wall lights must be both full cutoff and fully shielded. Task focused lighting at gas stations, ATM drive-throughs and similar uses approved by the Director needs an internal louver so the light lands on the task area and does not spill onto the pavement.
Parking lot fixtures face a height cap: the pole, pole support, fixture and equipment together are limited to the district height limit or thirty feet, whichever is less. Poles must be metal or another material acceptable to the Village Engineer, and wood poles are prohibited.
Facade lighting has its own shielding standard. Upward aimed building facade lighting cannot exceed 900 lumens, and all upward aimed light must be fully shielded and confined from projecting into the sky by eaves, roofs or overhangs. Facade light above 900 lumens must be fully shielded and aimed downward. Facade lighting must stay within the vertical surface of the wall it illuminates, and any that is measurable at ground level counts toward the maximum allowable light levels.
Small ornamental fixtures of 100 lumens or less and seasonal displays under 75 days are exempt.
Violations & Fines
Section 14.314 does not print a fine. Fixtures that fall short of the full cutoff, flat lens or shielding standards are nonconforming, and the section requires that lighting which does not conform be made to conform by means of alteration. Departures from full cutoff design are allowed only on the Director of Community Development's approval after the glare showing.
Frequently Asked Questions
Does Mount Prospect require full cutoff light fixtures?
Can I get approval for a fixture that is not full cutoff?
How tall can a parking lot light pole be in Mount Prospect?
Are lights that shine up on a building allowed?
Sources & Official References
Other rules in Mount Prospect
Compare Mount Prospect to another location·View the Illinois outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Dark Sky Rules in Nearby Cities
How other cities in Cook County handle dark sky rules.