Key Facts

Permit trigger: capacity
Over 3,000 gallons
Permit trigger: depth
Over three feet and six inches of water
Overhead wiring clearance
Ten feet horizontally from pool edge, diving structure or platforms
Safety fencing
Completely installed before filling the pool
Multiple-family pools
Water surface and pumps at least 50 feet from any lot line
Pool electrical fee (2026)
$120.00 plus circuits at $12.00 each

Summary

Roseville requires a building permit for any swimming pool with a capacity over 3,000 gallons or a depth of over three feet and six inches of water. The application must show the pool type and size plus a detailed site plan, and required safety fencing must be completely installed before the pool is filled.

A building permit shall be required for any swimming pool with a capacity over 3,000 gallons or with a depth of over three feet and six inches of water. The permit fee shall be as listed in the city fee schedule.

View official code

Official source re-checked November 3, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 2).

Full Breakdown

Section 905.01 sets the trigger: a building permit is required for any swimming pool with a capacity over 3,000 gallons or with a depth of over three feet and six inches of water, with the fee listed in the city fee schedule. Section 905.02 spells out the application. It must show the type and size of pool and a site plan indicating the location of the pool; the location of the house, garage, fencing and other improvements on the lot; structures on all adjacent lots; the filter unit, pump and wiring; backflush and drainage outlets; a grading plan, finished elevations and final treatment (decking, landscaping, etc.) around the pool; existing overhead or underground wiring, utility easements and trees; and any water heating unit.

Section 905.03 attaches conditions to the permit. Pools cannot sit beneath overhead utility lines or over underground utility lines. No pool can be placed under service drop conductors or other open overhead wiring, or within ten feet horizontally from the pool edge, diving structure, observation stands, towers or platforms. All construction access must be over the owner's land. Required safety fencing must be completely installed prior to filling a pool, and filling from fire hydrants or draining into public streets or drainageways requires permission of the appropriate city officials. Pool location in the yard is governed by section 1011.12(b)(4).

Other permits can apply. Removing an in-ground pool needs a demolition permit under section 901.07(d). The Appendix A electrical fee table lists a swimming pool (up to two inspections) at $120.00 plus circuits at $12.00 each. Pools for multiple-family dwellings must keep the water surface and pumps at least 50 feet from any lot line under section 905.04.

Violations & Fines

Section 102.01(a) makes a violation of the city Code a misdemeanor unless the Code provides otherwise: a fine not to exceed $1,000.00, imprisonment not to exceed 90 days, or both. Section 905.03(g) states that nuisances such as undue noise, lighting of adjacent property, health and safety hazards and damage to nearby vegetation shall not be permitted, and section 901.13 makes a permit no defense to a violation charge.

Frequently Asked Questions

When does a Roseville pool need a building permit?
Section 905.01 requires a permit for any swimming pool with a capacity over 3,000 gallons or with a depth of over three feet and six inches of water. The fee is the amount listed in the city fee schedule.
What must a pool permit application include?
Section 905.02 requires the type and size of the pool and a site plan showing the pool, house, garage, fencing, adjacent lot structures, filter unit, pump and wiring, backflush and drainage outlets, grading plan, utility easements, trees and any water heating unit.
Do I need the fence before I fill the pool?
Yes. Section 905.03(f) says required safety fencing shall be completely installed prior to filling a pool. Section 905.03(h) separately requires permission from the appropriate city officials before filling from a fire hydrant or draining into a public street.
Where can a pool not go in Roseville?
Section 905.03(b) bars pools beneath overhead utility lines or over underground utility lines, and 905.03(i) bars them under service drop conductors or within ten feet horizontally of the pool edge, diving structure, observation stands, towers or platforms.

Sources & Official References

Other rules in Roseville

All Roseville rules

Compare Roseville to another location·View the Minnesota swimming pools & spas overview

Get notified when Pool Permits in Roseville, MN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Pool Permits in Nearby Cities

How other cities in this county handle pool permits.

Saint Paul, MN
Some Restrictions