Moore, OK Building Safety: Carbon Monoxide Detectors (2026)
Key Facts
- CO alarm
- Required in appliance enclosure (§ 5-204, M2005.2)
- Door type
- Must be solid and self-closing
- Weatherstripping
- Matches exterior door air-leakage standard
- Rooms covered
- Sleeping rooms, toilet rooms, surgical rooms
- Enforcement
- Checked at mechanical inspection on permit
- Penalty
- Fines up to $500/day under § 1-108
Summary
In the City of Moore, Oklahoma, the city's amendment to Mechanical Code Section M2005.2 allows a fuel-burning appliance's combustion-air enclosure to be entered from a bedroom, toilet room or surgical room only through a solid, weather-stripped, self-closing door, and only if a carbon monoxide alarm is installed in that enclosure. Community Development enforces the mechanical code through the standard building permit and inspection process.
Section M2005.2, add verbiage to existing text: Add the word, [Existing] at the beginning of the second sentence and add the words: [sleeping rooms, toilet rooms, surgical rooms] in the middle of the second sentence; add a sentence after the second sentence to read: [Access to such enclosure may be from the bedroom or bathroom when through a solid door, weather-stripped in accordance with the exterior door air leakage requirements and equipped with an approved self-closing device and a carbon monoxide alarm is in place.]
Full Breakdown
Sec 5-204 adopts the 2018 International Residential Code with local amendments, one of which rewrites Section M2005.2 governing enclosures that house fuel-fired appliances such as furnaces and water heaters. Moore's amendment adds the word 'Existing' to the start of the second sentence, extends the listed room types to sleeping rooms, toilet rooms and surgical rooms, and inserts a new sentence permitting access from the bedroom or bathroom on one specific condition: the doorway must be a solid door, weather-stripped to the same air-leakage standard as an exterior door, fitted with an approved self-closing device, and the enclosure must have a carbon monoxide alarm installed.
Without all of those features together, an appliance enclosure cannot be entered directly from a bedroom or bathroom under the city's amended code. The rule is enforced as part of the mechanical inspection that accompanies a building or remodel permit, administered by the Community Development Department's building official under the same penalty structure that covers the rest of the building code. Because the amendment is tied to the 2018 IRC's mechanical provisions rather than a stand-alone city ordinance, it applies to one- and two-family construction and remodels reviewed under that code, and any conflict between it and a stricter state requirement is resolved in favor of whichever standard is more restrictive under Sec 5-203.
Violations & Fines
Installing or approving a bedroom or bathroom access door to a fuel-appliance enclosure without a self-closing, weather-stripped solid door and a carbon monoxide alarm fails the mechanical inspection required for the permit, and the building official can refuse approval or order the deficiency corrected. Continuing work after a stop-work order or occupying a building with a failed mechanical inspection is punishable under Sec 1-108, with fines up to $500 per day the violation continues.
Frequently Asked Questions
Does Moore require a carbon monoxide alarm near a furnace closet?
What kind of door does Moore require for a bedroom-accessed equipment closet?
Who enforces the carbon monoxide alarm rule in Moore?
Sources & Official References
Other rules in Moore
Compare Moore to another location·View the Oklahoma building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Carbon Monoxide Detectors in Nearby Cities
How other cities in this county handle carbon monoxide detectors.