Abington, PA Building Safety: Door Locking Hardware (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Height threshold
Over 6 stories or 65 feet
Governing section
Fire Prevention Code § 85-4(K)
Unlock exception
Street floor door only
Alternate exception
Fail-safe detector-activated lock
Enforcing official
Township Fire Marshal
Max fine
$300 per violation
Appeal deadline
30 days to Township Manager

Summary

Abington Township's Fire Prevention Code requires stair enclosure doors in buildings taller than six stories or 65 feet to stay unlocked on the inside. Section 85-4(K) rewrote F-1500.16 so occupants can always open a stairwell door during a fire, exempting only the street-floor door or a door held by a fail-safe electric lock wired to the detection system.

K. F-1500.16 shall read as follows: [Amended 6-13-1974 by Ord. No. 1377] F-1500.16 Special provisions for all high-rise multiple-occupancy, office, dwelling, institutional, educational or storage buildings with an elevation of more than six stories or 65 feet in height above the mean grade level: These buildings shall conform to the requirements of this section in addition to all other requirements of the codes of the Township of Abington. ( ... 2) Stairs. ... (e) All stair enclosures shall be provided with fire doors approved for Class B openings. Doors shall be provided with products-of-combustion closures as a means of positive closing and shall be interlocked with the fire command station during emergencies. All interior stair doors shall remain unlocked except on the street floor or where a fail-safe electric door lock is activated by the detector.

Full Breakdown

The Fire Prevention Code, adopted at § 85-1 from the 1990 BOCA National Fire Prevention Code, is amended chapter-wide at § 85-4. Subsection K rewrote F-1500.16 to add life-safety rules for every high-rise multiple-occupancy, office, dwelling, institutional, educational or storage building rising more than six stories or 65 feet above mean grade. Along with two-hour fire-resistance-rated stair towers, emergency telephones on at least every fourth floor and an intercommunication system tied to the fire command station, paragraph (2)(e) requires every stair enclosure to carry fire doors approved for Class B openings with positive-closing, products-of-combustion closures interlocked with the fire command station.

The operative sentence is direct: interior stair doors must remain unlocked at all times except on the street floor, or where a fail-safe electric door lock is activated by a detector so the door releases automatically if smoke or fire is sensed. The Fire Marshal administers the code and can order corrections under § 85-3; an applicant who disputes an interpretation can appeal to the Township Manager within 30 days under § 85-6. The Board of Commissioners retains power to modify the code's application on a written showing of practical difficulty under § 85-5, but the stair-door mandate applies to every qualifying high-rise regardless of when it was built, since existing structures had two years to comply once the provision was enacted.

Violations & Fines

Violating any Fire Prevention Code provision, including the stair-door locking rule, carries a fine of up to $300 per offense under § 85-8, with imprisonment up to five days if the fine and costs go unpaid. Each day the locked condition continues is a separate offense, and paying the fine never excuses the owner from correcting the violation or facing forced removal of the noncompliant lock.

Frequently Asked Questions

Which Abington buildings must keep stair doors unlocked?
Any multiple-occupancy, office, dwelling, institutional, educational or storage building in Abington Township that rises more than six stories or 65 feet above mean grade falls under § 85-4(K)'s high-rise stair-door rule, regardless of when it was constructed, since existing buildings had two years to comply once the provision was enacted.
Can a stairwell door in an Abington high-rise ever be locked?
Only in two situations: the door on the street floor, or a door fitted with a fail-safe electric lock that is wired to the building's fire detectors and releases automatically the instant smoke or heat is sensed. Every other interior stair door must remain unlocked so occupants can exit through the stairwell.
Who enforces the stair-door locking rule in Abington Township?
The Township Fire Marshal administers and inspects for compliance with the Fire Prevention Code under § 85-3. An owner who believes the rule was misapplied can appeal the Fire Marshal's decision to the Township Manager within 30 days under § 85-6.
What is the penalty for a locked stair door in an Abington high-rise?
Section 85-8 sets a fine of not more than $300 for each violation, with up to five days' imprisonment if the fine and prosecution costs are not paid. Each day the door remains improperly locked counts as a separate violation, and the Township can still force removal of the lock.

Sources & Official References

Other rules in Abington

All Abington rules

Compare Abington to another location·View the Pennsylvania building safety overview

Get notified when Door Locking Hardware in Abington, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.