Key Facts

Governing section
DMC Sec. 7.32.280, Appendix Ch. 10
Deadbolt throw
Minimum 1-inch projection
Cylinder
Minimum 5 pin tumblers, cylinder guard
Astragal (double doors)
Steel, minimum .125 inch thick
Aluminum frame jamb
Must resist 1,600 lbs of pressure
Window glazing
Burglary-resistant if pane over 96 sq in

Summary

Dublin's building security appendix sets exact hardware specifications for exterior doors: swinging doors need a deadbolt with at least a 1-inch throw and five-pin cylinder, double doors need steel astragals and flush bolts, and sliding patio doors and accessible windows have their own locking and glazing standards.

(1) Swinging exterior wood and steel doors shall be equipped as follows: (a) A single or double door shall be equipped with a double- or single-cylinder deadbolt. The bolt shall have a minimum projection of one (1) inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths (3/4) inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth (1/4) inch in diameter. ... (c) For the purpose of this section, doors leading from garage areas into a dwelling are exterior doors.

View official code

Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 2-26, passed March 3, 2026).

Full Breakdown

Dublin Municipal Code Sec. 34 Residential Code standards). Under subsection (B)(1)(a), swinging exterior wood and steel doors must have a single- or double-cylinder deadbolt with a bolt projection of at least 1 inch, built to resist cutting-tool attack, with at least 3/4-inch embedment into the strike, a cylinder guard, a minimum of five pin tumblers, and connecting screws at least 1/4 inch in diameter; garage-to-dwelling doors count as exterior doors for this rule. 125 inch thick covering the gap between the doors, welded or bolted with non-removable fasteners (subsection (B)(2)).

Aluminum-frame swinging doors need jambs able to withstand 1,600 pounds of pressure near the strike, with a comparable deadbolt or dog-bolt (subsection (B)(3)). Sliding patio glass doors must have a lock bolt that resists disengagement by manipulating the door, and doors accessible from grade need either an interior-mounted moving panel or an approved secondary lock (subsection (B)(5)(b),(c)). Accessible windows within 12 feet of the ground with panes over 96 square inches and a minimum dimension over 6 inches need burglary-resistant glazing or an equivalent approved method, unless visible from a public or private thoroughfare (subsection (B)(7)).

Violations & Fines

Constructing or altering a building without the required security hardware is enforced as a building code violation under Sec. 1.04.030: a misdemeanor with up to a $1,000 fine and six months in jail, or, at the city's discretion, an infraction. The Building Official can withhold final inspection approval under Sec. 7.28.590 until the required hardware is installed and verified.

Frequently Asked Questions

What kind of deadbolt does Dublin require on exterior doors?
Sec. 7.32.280(B)(1)(a) requires a single- or double-cylinder deadbolt with at least a 1-inch bolt projection, built to resist cutting tools, at least 3/4-inch embedment into the strike, a cylinder guard, and a minimum of five pin tumblers connected with 1/4-inch screws.
Does Dublin's door security code apply to garage entry doors?
Yes. Sec. 7.32.280(B)(1)(c) specifically states that for the purposes of the building security section, doors leading from garage areas into a dwelling are treated as exterior doors and must meet the same deadbolt and hardware standards.
What secures double exterior doors in Dublin?
Sec. 7.32.280(B)(2) requires the inactive leaf of a double door to have metal flush bolts embedded at least 5/8 inch into the head and threshold, plus a steel astragal at least .125 inch thick covering the gap, attached with welding or non-removable bolts on 10-inch centers.
Do sliding glass patio doors need a special lock?
Yes. Sec. 7.32.280(B)(5)(b) requires all sliding patio doors to have a lock bolt that resists disengagement from movement within its installation clearance, and doors accessible from ground level or a balcony need either an inside-mounted moving panel or an approved secondary lock.

Sources & Official References

Other rules in Dublin

All Dublin rules

California rules heatmap·Compare Dublin to another location·View the California building safety overview

Get notified when Door Locking Hardware in Dublin, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Door Locking Hardware in Nearby Cities

How other cities in Alameda County handle door locking hardware.

Oakland, CA
Some Restrictions
Livermore, CA
Some Restrictions
Berkeley, CA
Some Restrictions