Paola, KS Building Safety: Electrical Permits (2026)
Key Facts
- Adopted electrical code
- 2017 National Electrical Code, dated August 5, 2017
- Adoption ordinance
- Ordinance No. 3005, copy filed with the City Clerk
- Permit required
- Before installing, altering, repairing or replacing any electrical system
- Who issues the permit
- The Code Official, under § 4-105(a)
- Local amendment
- Arc-fault circuit interrupter on 15- and 20-ampere bedroom circuits
- Exempt work
- Minor repairs, radio and TV transmitters, temporary testing systems
- Fees
- Assessed under Section 4-301 per § 4-108
Summary
Paola adopts the 2017 National Electrical Code, dated August 5, 2017, by reference in City Code § 4-206, with a local arc-fault rule for bedroom circuits. Under § 4-105, anyone who installs, alters, repairs or replaces an electrical system first applies to the Code Official and obtains a permit.
(a) There is incorporated by reference, for the purpose of adopting regulations, provisions, terms and specifications for the control of buildings and structures within the unincorporated areas of the City of Paola, the 2017 National Electrical Code, dated August 5, 2017, as published by the National Fire Protection Association, Inc., excepting only such parts or portions thereof as are specifically deleted or amended by this Section and including such new and additional provisions added to said code by this Section. ... (3) National Electrical Code–amendments. The following Chapters, Sections and Subsections of the 2005 Edition of the National Electrical Code are hereby amended as follows. ... (B) 210.12(A) All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit bedrooms shall be protected by a listed arc-fault circuit interrupter, combination type installed to provide protection of the branch circuit.
Full Breakdown
Section 4-206 incorporates the 2017 National Electrical Code, dated August 5, 2017, as published by the National Fire Protection Association, Inc. Paola adopts it by reference through Ordinance No. 3005, and the section states that at least one copy is marked Official Copy as Adopted by Ordinance No. 3005 and filed with the City Clerk, open to inspection at all reasonable business hours. The adoption is subject to the parts the section specifically deletes or amends.
The section lists two local amendments. Amendment (A) rewrites NEC 90-2(b)(6) so that the Code's scope covers electrical systems, equipment and components, indoors and outdoors, that fall within the scope of Chapters 34 through 43 of the 2018 Edition of the International Residential Code. Amendment (B) addresses NEC 210.12(A): all 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed in dwelling unit bedrooms must be protected by a listed arc-fault circuit interrupter, combination type, installed to provide protection of the branch circuit. The section's text reads as printed, including its reference to the 2005 Edition of the National Electrical Code in the amendment lead-in and its reference to the unincorporated areas of the City of Paola.
The permit requirement sits in § 4-105(a). Any owner or authorized agent who intends to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system regulated by the code must first make application to the Code Official and obtain the required permit. The Code Official can issue an annual permit under § 4-105(a)(1) in place of an individual permit for each alteration to an already approved electrical installation, but only to a person, firm or corporation that regularly employs one or more qualified trade persons on premises the applicant owns or operates. The holder of an annual permit keeps a detailed record of alterations made under it, and the Code Official has access to those records at all times.
Section 4-105(b)(2) exempts three kinds of electrical work: minor repair work such as replacing fixtures or connecting approved portable electric equipment to approved permanently installed receptacles; radio and television transmitting equipment, though power supply wiring and tower and antenna installations stay covered; and temporary systems installed for testing or servicing electrical equipment. The exemption does not authorize work that violates the code. Section 4-108 sends permit fees to the schedule in Section 4-301.
Violations & Fines
Starting electrical work that § 4-105 covers without first applying to the Code Official and obtaining the permit breaks the building code. The exemption in § 4-105(b) does not authorize work done in violation of the code's provisions, so a repair that falls under the minor-repair exemption must still meet the adopted 2017 NEC. The text read for this page does not print a penalty figure for electrical work, so confirm any fine or stop-work consequence with the Community Development Department.
Frequently Asked Questions
Which National Electrical Code edition does Paola use?
Do I need a permit to replace a light fixture in Paola?
What is Paola's local amendment for bedroom circuits?
Can a business get one permit for repeated electrical alterations?
Who do I apply to for an electrical permit?
Sources & Official References
Other rules in Paola
Compare Paola to another location·View the Kansas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.