Sanford, FL Building Safety: Elevator Maintenance (2026)
Key Facts
- Maintenance standard
- ASME A17.1
- Inspection interval
- per ASME A17.1, Appendix N
- Certificate posting
- current certificate displayed or posted
- Minimum service
- at least 1 elevator running when building occupied
- Single-elevator exception
- may go down temporarily for testing/servicing
Summary
In the City of Sanford, Florida, Property Maintenance Code Section 606.1 requires every elevator, dumbwaiter and escalator to be maintained to ASME A17.1 and to display its current inspection certificate; Section 606.2 requires at least one passenger elevator to stay running whenever a building with elevators is occupied.
Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A 17.1. The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, be available for public inspection in the office of the building operator or be posted in a publicly conspicuous location approved by the code official. The inspection and tests shall be performed at not less than the periodic intervals listed in ASME A 17.1, Appendix N, except where otherwise specified by the authority having jurisdiction. ... In buildings equipped with passenger elevators, at least one elevator shall be maintained in operation at all times when the building is occupied.
Full Breakdown
Sanford's adopted Property Maintenance Code, at City Code Sections 18-101 and 18-102, governs vertical transportation equipment in Chapter 6, Section 606. Section 606.1 requires elevators, dumbwaiters and escalators to be maintained in compliance with ASME A17.1, and the most current certificate of inspection must be on display within the elevator, attached to the escalator or dumbwaiter, available for public inspection in the building operator's office, or posted in another publicly conspicuous, code-official-approved location. Inspections and tests must happen at least as often as the periodic intervals ASME A17.1, Appendix N sets, unless the authority having jurisdiction specifies otherwise.
Section 606.2 then imposes an operational duty specific to passenger elevators: in any building equipped with them, at least one elevator must stay in operation at all times the building is occupied. The only exception is a building with a single elevator, which may be taken out of service temporarily for testing or servicing. Because this sits inside the adopted Property Maintenance Code, a building owner who lets certificates lapse or who leaves every elevator down in a multi-elevator building faces the same Section 106.2 enforcement path as other property maintenance violations, routed through Chapter 26 code enforcement and, if needed, the special magistrate.
Violations & Fines
Operating without a current ASME A17.1 inspection certificate on display, or leaving every elevator out of service in an occupied multi-elevator building, violates Sections 606.1 and 606.2; the code official issues a notice of violation under Chapter 26, with a civil citation or special magistrate hearing for an uncorrected violation.
Frequently Asked Questions
How often must Sanford building elevators be inspected?
Can a building with multiple elevators take all of them out of service?
Where must the elevator inspection certificate be posted in Sanford?
Sources & Official References
Other rules in Sanford
Florida rules heatmap·Compare Sanford to another location·View the Florida building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.