Skip to main content
CityRuleLookup

Huntington Park, CA Building Safety: Green Building Code (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Permit trigger
New construction, additions and alterations (§ 6-2.411)
Standard
CALGreen, 24 CCR, Part 11
Plan approver, private property
City Building Official or designee
Performance security
Lesser of 3% of project cost or $30,000, minimum $1,000
Documentation deadline
No later than 30 days after completion
Infraction fine
$500, each day a separate offense

Summary

In the City of Huntington Park, California, anyone applying for a permit for new construction, additions or alterations must meet CALGreen under Municipal Code § 6-2.411, and covered projects must also file a construction and demolition waste management plan under Chapter 7-10 before a building or demolition permit issues.

§ 6-2.411. Compliance with CALGreen recycling requirements. (a) Persons applying for a permit from the City for new construction and building additions and alterations shall comply with the requirements of this section and all required components of the California Green Building Standards Code, 24 CCR, Part 11, known as CALGreen, as amended, if its project is covered by the scope of CALGreen or more stringent requirements of the City. If the requirements of CALGreen are more stringent than the requirements of this section, the CALGreen requirements shall apply. Project applicants shall refer to Sections 7-10.001 et seq. of the Huntington Park Municipal Code for complete CALGreen requirements. ... (3) Comply with CALGreen requirements and applicable law related to management of C&D, including diversion of organic waste in C&D from disposal.

Full Breakdown

Section 6-2.411 of the Huntington Park Municipal Code ties City permits to the California Green Building Standards Code, 24 CCR, Part 11, known as CALGreen. Persons applying for a City permit for new construction and building additions and alterations must comply with the section and all required components of CALGreen when the project falls within CALGreen's scope or the City's more stringent requirements. Where CALGreen is the stricter standard, it controls.

Subsection (b) makes compliance a condition of permit approval. Where five or more multi-family dwelling units are constructed on a building site, the project must provide readily accessible areas for storage and collection of blue container materials, consistent with the City's organic waste collection program, or comply with the recycling-space provisions at CALGreen Sections 4.408.1, 4.410.2, 5.408.1 and 5.410.1. New commercial construction or additions resulting in more than 30% of the floor area face the same space requirement. Every covered project must also comply with the City's construction and demolition ordinance.

That ordinance is Chapter 7-10. Section 7-10.001 states that its purpose is to fulfill the City's obligation to meet CALGreen and to reduce landfill waste from construction and demolition materials. Under § 7-10.030, no building or demolition permit is issued for a covered project until a waste management plan has been reviewed and approved, by the City Building Official or designee for private property and by the Public Works Director or designee for public property.

Section 7-10.040 requires a performance security calculated as the lesser of 3% of total cost of the entire project or $30,000.00, with a minimum of $1,000.00. The WMP Compliance Official can waive it if the total would be $500.00 or less. Diversion documentation is due before any occupancy permit and no later than 30 days after completion of a covered project (§ 7-10.050). Chapter 7-10 carries the amendment history Ord. 2016-953, eff. January 5, 2017, and § 6-2.411 carries Ord. 2021-03, eff. December 7, 2021.

Violations & Fines

Under § 7-10.080, the first failure to comply with Chapter 7-10 brings a written notice from the Department of Public Works with a correction deadline. Each later failure after written notice can draw a penalty not to exceed $500.00 levied by the Public Works Director. Any violation is also an infraction punishable by a fine of $500.00, each day is a separate offense, and the violation is a public nuisance. The performance security is forfeited if documentation is not provided within 30 days of project completion.

Frequently Asked Questions

Do I need a waste management plan before a demolition permit in the City of Huntington Park?
Yes for a covered project. Section 7-10.030 says no building or demolition permit is issued for any covered project unless a waste management plan has been reviewed and approved. Plans for private property go to the City Building Official or designee, and plans for work on public property go to the Public Works Director or designee.
How much is the performance security?
Section 7-10.040 sets it as the lesser of 3% of total cost of the entire project or $30,000.00, with a minimum of $1,000.00. The WMP Compliance Official can waive it if the total would be $500.00 or less. It is forfeited if the applicant fails to provide documentation within 30 days of project completion.
Can an applicant get an exemption from the diversion requirement?
Yes. Section 7-10.060 allows an exemption application when the waste management plan is submitted, based on lack of storage space on-site, contamination by hazardous substances, or low recyclability of specific materials. If the City finds compliance is possible, it informs the applicant in writing and the applicant has 30 days to resubmit a compliant plan.
How do I appeal a ruling under Chapter 7-10?
Under § 7-10.070, the applicant or any interested person can appeal a ruling of the WMP Compliance Official to the City Council in accordance with Section 1-4.01, and notice of appeal must be filed within 10 days of the ruling. A penalty under § 7-10.080 can be disputed by requesting a City Council hearing within 10 days.

Sources & Official References

Other rules in Huntington Park

All Huntington Park rules

California rules heatmap·Compare Huntington Park to another location·View the California building safety overview

Get notified when Green Building Code in Huntington Park, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Green Building Code in Nearby Cities

How other cities in Los Angeles County handle green building code.

South Gate, CA
Light Restrictions
Downey, CA
Some Restrictions
El Monte, CA
Some Restrictions
Long Beach, CA
Some Restrictions
Carson, CA
Some Restrictions
Santa Clarita, CA
Some Restrictions
Pasadena, CA
Some Restrictions
Palmdale, CA
Some Restrictions