Key Facts

Mandatory energy standard
Energy component of the adopted Building Code
LEED/USGBC certification
Optional desirable attribute, not required
Architectural desirables needed
5 of 9 categories under Figure 3-9(C)
Governing sections
Appendix B § 3.4.C (Fig. 3-9), § 3.4.F.15
Review point
Planning Department at plat/site plan stage

Summary

The City of Wylie does not operate a mandatory green building code. Appendix B's residential design standards, Figure 3-9(C) and Section 3.4.F.15, list USGBC or LEED certification for energy and water as one of nine optional desirable design attributes a new subdivision can choose from; every base standard only requires compliance with the Energy component of the adopted Building Code.

Conservation/ Sustainability Complies with Energy component of Building Code. Certified by USGBC or LEEDS for energy and water. ... 15.Conservation/Sustainability.a.Base Standard. Each residential dwelling unit must comply with the Energy component of the Building Code. b.Desirable Design Attributes. Each residential dwelling unit is certified by United States Green Building Council (USBG) or Leadership in Energy and Environmental Design (LEED).

Full Breakdown

Section 3.4 sets a two-tier system for new residential development in Wylie: every project must fully satisfy the Base Standard for each design element, and separately select a minimum number of Desirable Design Attributes to reach the level required by Figure 3-9's category totals; the Architectural category alone requires 5 of its 9 listed desirables. Under the Conservation/Sustainability line of Figure 3-9(C), the mandatory Base Standard is only that each residential dwelling unit comply with the Energy component of the adopted Building Code, the same energy code baseline every house in the city must meet regardless of design choices.

The Desirable option on the same line, repeated in the detailed text at Section 3.4.F.15, lets a builder claim credit toward the 5-of-9 architectural quota if the unit is certified by United States Green Building Council (USBG) or Leadership in Energy and Environmental Design (LEED). Nothing in Appendix B requires that certification; a developer can hit the 5-of-9 threshold entirely through the other eight desirables, such as upgraded porches, chimneys or garage size, without ever pursuing LEED or USGBC review. There is no separate green building chapter, no local energy-code overlay beyond the Building Code's energy component, and no fee schedule or inspection track tied to third-party green certification anywhere in the Code of Ordinances or Appendix A Fee Schedule. Planning staff verify which desirables a project selected at plat and site-plan review, not through a dedicated green-building permit.

Violations & Fines

There is no green-building mandate to violate. A development that fails to select at least 5 of the 9 Architectural desirables in Figure 3-9(C), with or without the LEED/USGBC option, does not meet the Residential Design Standards Review requirement of Section 3.4.C.1, and Planning can withhold plat or site plan approval until the required number of desirables, from any combination of the nine, is documented.

Frequently Asked Questions

Does Wylie require LEED or green building certification?
No. Appendix B Section 3.4 lists USGBC or LEED certification for energy and water as one optional Desirable Design Attribute among nine choices in the Conservation/Sustainability category; the only mandatory Base Standard is compliance with the Energy component of the adopted Building Code, which applies to every home regardless of certification.
What counts toward the design-standards requirement instead of LEED?
A project can satisfy its 5-of-9 Architectural desirable quota using any combination of the other options in Figure 3-9(C), including upgraded porches, larger garages, board-on-board fencing or automated irrigation, so LEED or USGBC certification is never the only path to compliance.
Who checks whether a subdivision met the design standards?
Planning Department staff verify the selected Base Standards and Desirable Design Attributes during plat and site plan review under Section 3.4.C.1, and can withhold approval until a project documents the required number of desirables from the Land Design, Street and Sidewalk, and Architectural categories.

Sources & Official References

Other rules in Wylie

All Wylie rules

Texas rules heatmap·Compare Wylie to another location·View the Texas building safety overview

Get notified when Green Building Code in Wylie, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Green Building Code in Nearby Cities

How other cities in Collin County handle green building code.

Frisco, TX
Light Restrictions
Plano, TX
Some Restrictions