Skip to main content
CityRuleLookup

Alameda, CA Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted plumbing code
2025 California Plumbing Code
Publisher
IAPMO
Gas shut-off trigger
Remodel value over $10,000
Post-sale deadline
90 days after closing
Device warranty
30 years
Enforcement
Administrative citation, Art. 1-7

Summary

Alameda adopts the 2025 California Plumbing Code by reference as the Alameda Plumbing Code and layers on a local seismic gas shut-off valve mandate for new construction and remodels over ten thousand dollars.

13-6.1 - Adoption of California Plumbing Code, as amended. The California Plumbing Code, 2025 Edition, published by the International Association of Plumbing and Mechanical Officials, including Appendix Chapters A, B, D through G, I and L, is adopted by reference and made a part hereof as if fully set forth herein at length, and shall be known as the Alameda Plumbing Code. Any conflicts between the requirements contained in the Current Alameda Plumbing Code Chapter I, Division II Administration and the 2025 Alameda Administrative Code shall be controlled by the latter.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 74).

Full Breakdown

1 adopts the California Plumbing Code, 2025 Edition, published by the International Association of Plumbing and Mechanical Officials, including Appendix Chapters A, B, D through G, I and L, by reference as the Alameda Plumbing Code, and specifies that any conflict between that code's own administration chapter and the Alameda Administrative Code is resolved in favor of the Administrative Code. 2 requires the Building Official to keep a copy available for public examination. 8 to require an approved seismic gas shut-off device or an excess-flow gas shut-off device, certified by the State Architect, downstream of the gas utility meter in any new commercial, industrial, or residential building for which a permit is first issued, and in any existing residential, commercial, or industrial building where fuel-gas piping is altered or added to and the value of that work exceeds ten thousand dollars.

The device must also be installed within ninety days after a real-property sale closes, and in any residential building already identified as a soft-story building under Ordinance 2989. Installation must be done by a state-licensed contractor, and the device must carry a thirty-year warranty against defects. 8, and violations are subject to administrative citations under Article 1-7 of the Alameda Municipal Code.

Violations & Fines

Failing to install a required seismic or excess-flow gas shut-off device on qualifying new construction, a remodel over ten thousand dollars, or within ninety days of a property sale is enforceable by administrative citation under Article 1-7 of the Alameda Municipal Code, at the Building Official's discretion. As with other permitted trades, plumbing work commenced without a permit triggers the Section 109.4.1 investigation fee under the Alameda Administrative Code, and failed inspections are subject to the Section 109.7 reinspection fee.

Frequently Asked Questions

What plumbing code applies to permits in Alameda?
Section 13-6.1 adopts the California Plumbing Code, 2025 Edition, published by the International Association of Plumbing and Mechanical Officials, by reference as the Alameda Plumbing Code, including Appendix Chapters A, B, D through G, I and L.
Does Alameda require an automatic gas shut-off valve?
Yes. Section 13-6.3 amends Plumbing Code Section 1211.8 to require a seismic or excess-flow gas shut-off device downstream of the gas meter on new buildings, on remodels adding or altering gas piping valued over ten thousand dollars, and within ninety days of a property sale.
Who can install a required gas shut-off device in Alameda?
Section 1211.8.5 requires installation by a contractor licensed in the appropriate classification by the State of California, following the manufacturer's instructions, and the device must carry a thirty-year warranty against defects.

Sources & Official References

Other rules in Alameda

All Alameda rules

California rules heatmap·Compare Alameda to another location·View the California building safety overview

Get notified when Plumbing Permits in Alameda, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in Alameda County handle plumbing permits.

Oakland, CA
Some Restrictions
Livermore, CA
Some Restrictions
Fremont, CA
Some Restrictions
Berkeley, CA
Some Restrictions
Hayward, CA
Some Restrictions
San Leandro, CA
Some Restrictions