Key Facts
- LDR district
- 30 feet maximum building height
- LMDR district
- 35 feet maximum building height
- Accessory buildings
- 15 feet; 9 feet wall height
- Accessory vs house
- Cannot exceed height of the principal structure
- Exempt structures
- Flagpoles, church spires, belfries, water towers and others under 1011.07
Summary
Roseville caps building height at 30 feet in the Low Density Residential district under Table 1004.09, and at 35 feet in the Low to Medium Density Residential district under Table 1004.10. Detached accessory buildings are held to 15 feet with a 9-foot wall under Table 1004.02. Section 1011.07 exempts specific structures such as flagpoles and church spires.
(b) Dimensional standards. Specific dimensional standards developments in the LDR district are established in the table below but developments may be organized according to section 1004.05 . Table 1004.09 One-Family Two-Family Courtyard Cottage ... Maximum building height 30 feet
Full Breakdown
Section 1004.09(b) of the Roseville City Code prints a maximum building height of 30 feet in Table 1004.09 for the Low Density Residential (LDR) district. That single figure sits across the one-family, two-family and courtyard cottage columns, so a house, duplex or cottage in LDR uses the same cap. The neighboring Low to Medium Density Residential (LMDR) district in section 1004.10 prints a maximum building height of 35 feet in each of its four columns: one-family, two-family, three- and four-family, and attached and courtyard cottage.
Accessory buildings have a lower ceiling. Table 1004.02 in section 1004.02 sets maximum height at 15 feet with a 9-foot wall height for detached storage buildings serving one- and two-family dwellings. A footnote adds that, notwithstanding the allowed maximum height, the height of an accessory building shall not exceed the height of the principal structure. An accessory storage building greater than 12 feet in height must also have exterior design and materials similar to or compatible with the principal structure.
Section 1011.07(a) applies the height limits of each zoning district to all buildings and structures, then exempts a short list: church spires, belfries, cupolas and domes which do not contain usable space, monuments, water towers, fire and hose towers, observation towers, flagpoles, and electrical transmission towers. Heights for the medium and high density, mixed-use and other districts sit in their own chapters and are not covered by the Table 1004.09 figure quoted here. Permits for detached accessory buildings are required before construction under section 1004.02(f), and the Community Development Department administers the residential district standards.
Violations & Fines
Section 1002.02 makes it a misdemeanor to violate, neglect or refuse to comply with any provision of Title 10, and each day a violation continues is a separate offense. Under section 102.01(a), unless the Code provides otherwise, the penalty is a fine not to exceed $1,000.00, imprisonment not to exceed 90 days, or both, plus costs of prosecution. Building above the Table 1004.09 height figure is a violation of the dimensional standards.
Frequently Asked Questions
How tall can a house be in Roseville's Low Density Residential district?
How tall can a Roseville shed or detached garage be?
Which structures are exempt from Roseville's height limits?
What is the penalty for building over the height limit in Roseville?
Sources & Official References
Other rules in Roseville
Compare Roseville to another location·View the Minnesota building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Structure Height Limits in Nearby Cities
How other cities in this county handle structure height limits.