Elevator Maintenance

Boca Raton requires every elevator to remain available to fire rescue personnel at all times and to meet Florida's Elevator Safety Code. Emergency auxiliary power must run backup elevators for at least 24 hours, switch on within 10 seconds, and undergo documented weekly testing under Section 7-33.

Boca Raton Elevator Fire Safety & Maintenance Rule

Some Restrictions

Boca Raton, FL Code of Ordinances § 7-33

All elevators shall be available for use by fire rescue services department personnel at all times. The controls for elevators shall satisfy all requirements contained in Chapter 61C-5, Florida Administrative Code (the Florida Elevator Safety Code)...(1)Emergency auxiliary power.(a)Emergency auxiliary electrical power shall be available in all elevators equipped with a key switch for use by fir...

Fire Sprinkler Requirements

Any automatic fire sprinkler system installed in a Boca Raton building must be listed by a nationally recognized testing laboratory and wired to automatically transmit an alarm to an approved central monitoring station under Section 7-60. The fire rescue services department keeps the official list of approved monitoring companies.

Boca Raton Automatic Fire Sprinkler System Rule

Some Restrictions

Boca Raton, FL Code of Ordinances § 7-60(1)

In addition to complying with the Florida Fire Prevention Code, the Florida Building Code, and the state fire marshal's rules and regulations, any automatic or manual fire alarm signal system, automatic fire-extinguishing, or automatic fire detection system hereafter installed, shall be listed by a Nationally Recognized Testing Laboratory ("NRTL") approved in accordance with the provisions of F...

Childcare Center Rules

Boca Raton requires new child care and adult care centers to sit on at least 10,000 square feet with 100 feet of street frontage, surround play areas with a 6-foot fence or wall, and observe fixed operating-hour cutoffs near residential districts.

Boca Raton Child Care Center Zoning Standards

Some Restrictions

Boca Raton City Code Secs. 28-1416, 28-1417, 28-1418, 28-1423

The regulations in this division shall apply to all new child care and adult care centers in the city. ... Minimum lot area under this division shall be 10,000 square feet with a minimum street frontage of 100 linear feet. ... A 6-foot-high fence or wall shall surround all play areas accessory to child care centers. ... All care centers located in or adjacent to residential districts shall not ...

Carbon Monoxide Detectors

New buildings and new parking structures in Boca Raton must install carbon monoxide detection systems under Section 7-60(6) of the fire code. The devices must send a supervisory signal at 99 parts per million and trigger a full building evacuation alarm once CO exceeds 199 parts per million.

Boca Raton Carbon Monoxide Detector Rule

Some Restrictions

Boca Raton, FL Code of Ordinances § 7-60(6)

(6)Carbon monoxide detection systems shall be installed in new buildings as required by the FFPC, NFPA 720, and NFPA 72. Carbon monoxide detection systems shall be installed in new parking structures as required in NFPA 88A. Such installed carbon monoxide detection devices shall be programmed to provide a supervisory signal to the fire alarm panel and any area attended by security or staff at a...

Building Permits

Any contractor, owner, or authorized agent who wants to construct, enlarge, alter, repair, move, or demolish a building in Boca Raton, or install, alter, or replace an electrical, gas, mechanical, plumbing, fire-protection, or impact-resistant covering system regulated by the city's building code, must first file an application with the building official and obtain a permit under Sec. 19-62 before starting work.

Boca Raton Building Permit Requirements

Some Restrictions

Boca Raton Code of Ordinances § 19-62

Any contractor, owner, or agent authorized in accordance with F.S. ch. 489, who intends to construct, enlarge, alter, repair, move, demolish, or change the use and occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any impact-resistant coverings, electrical, gas, mechanical, plumbing or fire protection system, or accessible or flood re...

Electrical Permits

Boca Raton enforces electrical work through Chapter 27 of the Florida Building Code, Building, plus the National Electrical Installation Standards, applying to every installation, alteration, repair or replacement of electrical systems, equipment, appliances and fixtures. The building official reviews applications and issues permits before any covered work begins.

Boca Raton Electrical Code Adoption and Permits

Some Restrictions

Boca Raton Code of Ordinances Sec. 19-9

(1)The provisions of Chapter 27 of the Florida Building Code, Building; fire protection provisions of this building code and FFPC shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto.(2)The provisions of the National Electrical Installations Standards shall apply to all electrical ...

Plumbing Permits

Boca Raton enforces plumbing work through the Florida Building Code, Plumbing, covering installation, alteration, repair and replacement of plumbing systems, equipment, appliances and fixtures, and any water, sewage or medical gas system connection. The building official reviews applications and issues permits before any covered plumbing work begins.

Boca Raton Plumbing Code Adoption and Permits

Some Restrictions

Boca Raton Code of Ordinances Sec. 19-12

The provisions of the Florida Building Code, Plumbing; fire protection provisions of this building code and FFPC shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system.

Building Inspections

Section 19-156 lists every inspection Boca Raton's building official must perform stage by stage, from foundation and slab through framing, roofing, and final, for building, electrical, plumbing, mechanical, gas, and swimming pool work, and the building official decides the timing and sequence of when each inspection happens.

Boca Raton Building Inspection Stages

Some Restrictions

Boca Raton Code of Ordinances § 19-156(1),(2)

The building official, upon notification from the permit holder, shall make the following inspections and such other inspections the building official deems necessary, and shall either approve that portion of the construction or shall notify the permit holder of any violations which must be corrected in order to comply with the building code. The building official shall determine the timing and...