Skip to main content
CityRuleLookup

Dearborn Heights, MI Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential elevation standard
Lowest floor at or above base flood elevation
Nonresidential alternative
Floodproofing under Sec. 15-58
Manufactured home anchoring
Ties resisting 4,800-lb force
Certification required from
Registered engineer or architect
Variance authority
Zoning Board of Appeals
First offense fine
$75 municipal civil infraction

Summary

In the City of Dearborn Heights, Section 15-57 requires the lowest floor, including the basement, of any new or substantially improved residential structure in a special flood hazard area to be elevated to or above the base flood elevation. Everything below that floor must resist hydrostatic and hydrodynamic loads and buoyancy, and a registered engineer or architect may have to certify compliance.

Sec. 15-57. - Residential construction. All new construction or substantial improvement of any residential structure in all areas of special flood hazard shall have the lowest floor, including the basement, elevated to or above the base flood elevation. That part of the structure below the lowest floor shall have structural components which are water-resistant and are capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Certification by a registered professional engineer or architect that the standards of this subsection are satisfied may be required.

Full Breakdown

Section 15-57 of the Dearborn Heights City Code requires that all new construction or substantial improvement of a residential structure anywhere in a special flood hazard area have its lowest floor, including any basement, elevated to or above the base flood elevation shown on the FEMA maps adopted at Sec. 15-8. The part of the structure below that lowest floor must have structural components that are water-resistant and capable of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy, and the Building and Engineering Director may require a registered professional engineer or architect to certify that these standards are met.

Section 15-58 gives commercial, industrial and other nonresidential structures an alternative: instead of elevating the lowest floor to the base flood elevation, the owner may floodproof the building so it is watertight, with walls substantially impermeable to water and structural components able to resist the same hydrostatic and hydrodynamic loads, again certified by a registered engineer or architect and filed with the Building and Engineering Director. Manufactured homes get their own elevation rule at Section 15-59: homes placed or substantially improved in Zones A1-30, AH and AE must sit on a permanent foundation with the lowest floor at or above the base flood elevation and be anchored with over-the-top and frame ties capable of resisting a 4,800-pound force.

A property owner who cannot meet the elevation standard may seek a variance from the zoning board of appeals under Sections 15-81 through 15-83, but a variance is barred inside a designated floodway if it would raise base flood levels, and any variance granted must include written notice of the resulting flood insurance cost.

Violations & Fines

Flood damage prevention is not classified for the special civil-infraction fine schedule, so building below the required base flood elevation is enforced as a general municipal civil infraction under Sec. 1-10(f): $75 for a first violation, $250 for a repeat within six months, and $500 for any further repeat, plus costs, with each day of noncompliance a separate offense. The Building and Engineering Director can also refuse to certify the structure, blocking occupancy and affecting flood insurance cost.

Frequently Asked Questions

How high must my house sit above flood level?
Section 15-57 requires the lowest floor, including any basement, of a new or substantially improved residential structure in a special flood hazard area to be elevated to or above the base flood elevation shown on the FEMA maps adopted at Section 15-8.
Can a commercial building avoid elevating instead?
No. Section 15-58 lets a commercial, industrial or other nonresidential structure be floodproofed instead, so it is watertight with walls substantially impermeable to water and structural components able to resist the same hydrostatic and hydrodynamic loads, certified by a registered engineer or architect.
Do manufactured homes have a different elevation rule?
Section 15-59 requires a manufactured home placed or substantially improved in Zones A1-30, AH or AE to sit on a permanent foundation with its lowest floor at or above the base flood elevation, anchored with over-the-top and frame ties capable of resisting a 4,800-pound force.

Sources & Official References

Other rules in Dearborn Heights

All Dearborn Heights rules

Compare Dearborn Heights to another location·View the Michigan environmental rules overview

Get notified when Flood Elevation Requirements in Dearborn Heights, MI changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Wayne County handle flood elevation requirements.

Dearborn, MI
Some Restrictions
Detroit, MI
Some Restrictions
Livonia, MI
Some Restrictions