Skip to main content
CityRuleLookup

Rowlett, TX Environmental Rules: Flood Elevation Requirements (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential freeboard
Lowest floor 2 ft above base flood elevation
Nonresidential option
2 ft freeboard or certified watertight design
Enclosure vent rule
1 sq in opening per sq ft, openings ≤1 ft above grade
Certifier required
Registered engineer, architect, or land surveyor
Manufactured homes
Permanent foundation, lowest floor 2 ft above BFE
RV exemption window
Fewer than 180 consecutive days on site

Summary

Rowlett requires new and substantially improved residential structures in mapped flood hazard areas to elevate the lowest floor, including any basement, two feet above the base flood elevation. Nonresidential buildings must meet the same two-foot freeboard or be engineered watertight below that level, with a licensed professional certifying compliance to the floodplain administrator.

Sec. 82-48. - Specific standards. In all areas of special flood hazards where base flood elevation data has been provided ... the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 82-45(a), is satisfied. (2) Nonresidential construction. New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to two feet above the base flood level or ... be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 29).

Full Breakdown

Section 82-48 sets the specific elevation standards that apply once base flood elevation data has been provided under §§ 82-37, 82-44(8) or 82-49(3). For residential construction, new buildings and substantial improvements must have the lowest floor, including any basement, elevated to two feet above the base flood elevation, and a registered professional engineer, architect or land surveyor must certify that standard to the floodplain administrator under § 82-45(a). Nonresidential structures, commercial, industrial or otherwise, have two compliance paths: elevate the lowest floor two feet above base flood level, or design the structure watertight below that level with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads; an engineer or architect must develop or review the design and certify it, and the administrator keeps a record of the certified floodproofed elevation.

Fully enclosed areas below the lowest floor used only for parking, building access or storage must be engineered to automatically equalize hydrostatic flood forces, or meet minimum criteria: at least two openings on separate walls totaling one square inch of net area per square foot of enclosed area, with the bottom of every opening no higher than one foot above grade. Manufactured homes placed in Zone A must be elevated and anchored against flotation, collapse or lateral movement using methods such as frame ties to ground anchors; homes placed or substantially improved in Zones A1-30, AH and AE outside an existing manufactured home park, in a new or expanded park, or in a park where a home was substantially damaged by flood, must sit on a permanent foundation with the lowest floor two feet above base flood elevation.

Recreational vehicles in those same zones must either stay fewer than 180 consecutive days, remain fully licensed and highway-ready, or meet the same permit, elevation and anchoring standards as manufactured homes.

Violations & Fines

Constructing, locating, extending, converting or altering a structure without meeting the § 82-48 elevation and floodproofing standards violates the floodplain article and is a misdemeanor under § 82-53, fined up to $500.00 per violation plus all costs and expenses of the case. A structure built without the required elevation or floodproofing certification is presumed in violation until the certifying documentation is produced, and the city may pursue other lawful remedies cumulatively.

Frequently Asked Questions

How high above base flood elevation must a Rowlett home be built?
Two feet. Section 82-48(1) requires the lowest floor, including any basement, of new construction and substantial improvements to residential structures to be elevated two feet above the base flood elevation, certified to the floodplain administrator by a registered engineer, architect or land surveyor.
Can a Rowlett commercial building skip the two-foot elevation?
Only if it is dry-floodproofed instead. Section 82-48(2) lets nonresidential structures either elevate two feet above base flood level or be engineered watertight below that level, with an engineer or architect certifying the design and the administrator recording the certified floodproofed elevation.
Do enclosed garages below the flood elevation need special venting in Rowlett?
Yes. Section 82-48(3) requires enclosed areas below the lowest floor used for parking, access or storage to auto-equalize flood forces, meeting a minimum of two openings on separate walls totaling one square inch per square foot of enclosed area, with opening bottoms no higher than one foot above grade.

Sources & Official References

Other rules in Rowlett

All Rowlett rules

Texas rules heatmap·Compare Rowlett to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Rowlett, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Dallas County handle flood elevation requirements.

Grand Prairie, TX
Some Restrictions
Garland, TX
Some Restrictions
Mesquite, TX
Some Restrictions
Richardson, TX
Some Restrictions
Irving, TX
Significant Restrictions
Dallas, TX
Significant Restrictions
DeSoto, TX
Significant Restrictions