Smyrna, GA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- Smyrna Code Sec. 54-62(1) and (2)
- Required lowest floor
- No lower than three feet above base flood elevation
- Flood-proofing alternative
- Nonresidential only, water tight to three feet above base flood elevation
- Enclosure openings
- One square inch per square foot, bottom within one foot of grade
- Existing park pier option
- Reinforced piers no less than 36 inches above grade
- Fine for violations
- Not more than $2,500.00 per offense
Summary
In the City of Smyrna, Georgia, Sec. 54-62 requires the lowest floor of new construction and substantial improvements, basement included, to sit no lower than three feet above the base flood elevation wherever that elevation is available. Nonresidential buildings can flood-proof to the same three-foot margin instead, with an engineer or architect certifying the design.
(1)New construction and substantial improvements: ... Where base flood elevation data are available, new construction or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation. ... (2)Nonresidential construction: New construction or the substantial improvement of any structure located in A1-30, AE, or AH zones, may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to three feet above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
Full Breakdown
The elevation rule sits in Sec. 54-62, Specific standards, in Article III of Chapter 54. Wherever base flood elevation data are available in an area of special flood hazard, new construction or substantial improvement of any structure or manufactured home must have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation. The Code defines base flood as the flood with a one percent chance of being equaled or exceeded in any given year, so the three-foot freeboard margin sits on top of that flood level.
Nonresidential buildings in A1-30, AE or AH zones have an alternative: flood-proofing in lieu of elevation. The structure and its utility and sanitary facilities must be designed water tight to three feet above the base flood elevation, and a registered professional engineer or architect must certify the design (Sec. 54-62(2)). Manufactured homes get the same three-foot rule under Sec. 54-62(3). In an existing manufactured home park, a home can instead sit with its chassis supported by reinforced piers of no less than 36 inches in height above grade. Recreational vehicles must be licensed and ready for highway use, or meet the new-construction anchoring and elevation requirements.
The paperwork tracks the number. The permit application must show the elevation of the lowest floor in relation to mean sea level or highest adjacent grade (Sec. 54-37(1)), and once the lowest floor is complete the permit holder must provide an as-built certification prepared by a registered land surveyor or professional engineer. The city engineer verifies and records the actual elevation (Sec. 54-38(4)).
Fully enclosed space below the lowest floor needs at least two openings with a total net area of not less than one square inch for every square foot of enclosed area, with the bottom of every opening no higher than one foot above grade. That space is limited to parking of vehicles, limited storage of maintenance equipment, or entry to the elevated area, and it cannot be partitioned or finished into rooms (Sec. 54-61(4)).
Violations & Fines
Building below the required elevation violates Chapter 54, a misdemeanor punishable under Sec. 54-13 by a fine of not more than $2,500.00 plus costs, with each day counted as a separate offense. Before that point the city engineer can halt the job: failure to submit the lowest-floor certification, or to correct deficiencies found in review, is cause for a stop-work order under Sec. 54-37, and work before certification proceeds at the permit holder's risk.
Frequently Asked Questions
How high above the base flood elevation must a Smyrna building be?
Can a commercial building flood-proof instead of elevating?
Who certifies the finished floor elevation?
What happens if a variance lowers the required floor elevation?
Sources & Official References
Other rules in Smyrna
Compare Smyrna to another location·View the Georgia environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Cobb County handle flood elevation requirements.