Skip to main content
CityRuleLookup

West Jordan, UT Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Residential Standard
Lowest floor above base flood elevation
Manufactured Home Margin
At least 1 ft above base flood elevation
Nonresidential Alternative
Certified floodproofing to base flood level
Enclosure Vents
1 sq in per sq ft, 2 openings minimum
Certifying Party
Registered professional engineer or architect

Summary

West Jordan requires new construction and substantial improvements in a special flood hazard area to have the lowest floor elevated above the base flood elevation. Manufactured homes placed in the R-M zone must sit at least one foot above base flood elevation on a permanent, anchored foundation, and nonresidential buildings can floodproof instead if a licensed engineer certifies the design.

A. Areas Of Special Flood Hazard: In all areas of special flood hazard where base flood elevation data have been provided, the following standards shall apply: 1. New construction and substantial improvement of any residential structure, and placement of manufactured homes, shall have the lowest floor, including basement, elevated above the base flood elevation. ... F. Manufactured Homes: ... All manufactured homes that are placed or substantially improved in the R-M zone (residential, mobile home) shall be elevated and adequately anchored on a permanent foundation such that the lowest floor of the manufactured home is a minimum of one foot (1') above the base flood elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-38: Code current through: Ord. 26-33, passed 6-23-2026).

Full Breakdown

Section 13-6E-9 of the Floodplain Overlay Zone article sets West Jordan's elevation and floodproofing standards. Under subsection A(1), new construction and substantial improvement of any residential structure, plus placement of manufactured homes, must have the lowest floor, including any basement, elevated above the base flood elevation. Subsection A(2) gives commercial, industrial and other nonresidential structures a choice: elevate the lowest floor the same way, or floodproof the building so it is watertight below the base flood level, with walls that resist hydrostatic and hydrodynamic loads and buoyancy, certified by a registered professional engineer or architect and filed with the city administrator.

Subsection F adds a specific freeboard-style margin for manufactured homes: any manufactured home placed or substantially improved in the R-M (residential mobile home) zone must be elevated and anchored on a permanent foundation so the lowest floor sits at least one foot above the base flood elevation, using methods such as over-the-top and frame ties to ground anchors, in addition to the wind-resistance anchoring already required. Subsection G requires enclosed areas below the lowest floor used only for parking, building access or storage to have flood vents: at least two openings with a combined net area of one square inch per square foot of enclosed area, with the bottom of each opening no higher than one foot above grade, unless a licensed engineer certifies an equivalent design.

Structural storage for chemicals, explosives or other hazardous materials must sit above the base flood elevation or be floodproofed against container flotation under subsection C.

Violations & Fines

Section 13-6E-8(B) requires the development permit application itself to show the elevation, in relation to mean sea level, of the lowest floor of every proposed structure, and a licensed engineer's certification for any nonresidential floodproofing; the city engineer, as floodplain administrator, records that elevation data and can refuse to sign off on a certificate of occupancy for a structure that was not built to the certified elevation or floodproofing standard.

Frequently Asked Questions

How high above flood level must a West Jordan home be built?
Section 13-6E-9(A)(1) requires the lowest floor, including any basement, of new or substantially improved residential structures in a special flood hazard area to sit above the base flood elevation. The code does not set a separate freeboard margin for standard homes beyond reaching that base flood elevation line.
Is there an extra elevation margin for manufactured homes?
Yes. Section 13-6E-9(F) requires manufactured homes placed or substantially improved in the R-M zone to be elevated and anchored on a permanent foundation so the lowest floor sits at least one foot above the base flood elevation, using methods like over-the-top and frame ties to ground anchors.
Can a commercial building in the floodplain skip elevating its floor?
Yes, if it floodproofs instead. Section 13-6E-9(A)(2) lets nonresidential structures floodproof rather than elevate, provided the design is watertight below the base flood level, resists hydrostatic and hydrodynamic loads, and is certified by a registered professional engineer or architect who files that certification with the city.

Sources & Official References

Other rules in West Jordan

All West Jordan rules

Compare West Jordan to another location·View the Utah environmental rules overview

Get notified when Flood Elevation Requirements in West Jordan, UT changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Salt Lake County handle flood elevation requirements.

West Valley City, UT
Some Restrictions
Salt Lake City, UT
Some Restrictions
South Jordan, UT
Some Restrictions
Sandy, UT
Some Restrictions