Yuba City, CA Fire Regulations: Propane Storage (2026)
Key Facts
- LP-gas storage cap
- 2,000 gallons citywide (IFC 6104.2)
- Legacy facility rule
- Continues until 90 days unused
- Explosives storage
- Prohibited citywide (Sec. 5604)
- Class I/II liquid tanks
- 15,000-gal cap, only in listed zones
- Enforcing officials
- Fire Chief and Fire Marshal
Summary
Yuba City caps the citywide storage of liquefied petroleum gas at 2,000 gallons under a local amendment to Fire Code Section 6104.2, found at Municipal Code Sec. 4-5.02. Facilities that already exceeded that limit before the amendment can keep operating until the tanks sit unused for 90 straight days, but cannot expand beyond safety-driven modifications.
Section 6104.2 The limits referred to in Section 6104.2 restricting the storage of over 2000 gallons of liquefied petroleum gas is hereby established as the City limits. Exception: Existing facilities having either single containers or multiple containers with aggregate capacity of over 2000 gallons of liquefied petroleum gas will be allowed to have their use contained until such time as the tank(s) are not used for a period of ninety (90) days. Other than required modifications necessary to bring the facility into compliance with safety regulations, there shall be no expansion of any existing facility within the City limits.
Full Breakdown
Sec. 2 to set the City's storage limit for liquefied petroleum gas at 2,000 gallons; above that aggregate, whether in one tank or several, a facility falls outside what the Fire Code allows within Yuba City limits. Facilities that already held more than 2,000 gallons before the amendment took effect keep the right to continue that use, but only until the tanks sit idle for 90 consecutive days, at which point the nonconforming use lapses. Existing over-limit facilities also cannot expand, except for modifications required to bring the site into compliance with safety regulations; no other growth of an existing facility above the cap is allowed anywhere in the City.
The same set of Fire Code amendments addresses related hazardous storage: Section 5604 prohibits the manufacture of explosives and the storage of explosives or blasting agents anywhere within City limits, with a narrow exception for small arms ammunition, primers, smokeless powder, and black sporting powder that meet Title 19 of the California Code of Regulations, and the Fire Chief or Fire Marshal can further limit the quantity of explosive material allowed at any location. 4, except in A, AH, M-1, M-2, C-3, and CM zones, where individual and aggregate tank capacity is capped at 15,000 gallons per parcel and tanks must be protected by concrete-filled steel posts and anchored against flotation in a flood.
Violations & Fines
Exceeding the 2,000-gallon propane limit, expanding a legacy over-limit facility, or storing explosives or blasting agents outside the small-arms-ammunition exception is enforced through the Fire Code's general citation and stop-work authority under Sec. 4-5.02, with the Fire Marshal empowered to further restrict quantities at any site. Because Yuba City sits behind Feather River levees, above-ground tanks permitted in industrial and commercial zones must also be anchored to resist flotation during flooding, a requirement enforced at plan review before a tank installation permit is issued.
Frequently Asked Questions
How much propane can be stored in Yuba City?
What happens to a propane facility that already exceeded 2,000 gallons?
Can explosives be stored in Yuba City?
Where can above-ground flammable liquid tanks be installed?